9. TROUBLESHOOTING
MALFUNCTION
SOLUTIONS
Fluid losso from accessories
and/or gun
Check for the black gasket cod. CVPOR to be correctly placed
on each extension and on the gun nozzle
Red light does not turn on
Check that the power cable is correctly connected, that power
is on in the socket, and that the switch is in position 1. If the
machine is running correctly but the red light does not turn
on, the light must be replaced. If the machine is not working
firstly change the socket and/or check for the main switch to
be correctly functioning.
Liquid is not delivered
The pump is running but is not drawing:
check for the suction pipe to be immersed in the fluid and
for the filter to be clean / rinse the pump with clean water /
replace the pump.
The pump is not running:
check for the gun plug to be correctly inserted / check that the
gun is working correctly / check the internal electric board /
replace the pump.
The blowing motor does not
work
Check for the gun plug to be correctly inserted/ check that the
gun is working correctly / check the internal electric board /
check the blowing motor.