25
MAGIC VAPOR SANI
ENGLISH
place a container at the feet of the machine and open gently
the drain valve to let the residual water get out. If no water
comes out check the output for limescale. In case of limescale
inside the boiler, it is possible to pour inside it a glass of water
mixed with vinegar. Then shake and empty the boiler, then rin-
se with water. It is recommended not to use any anti-limescale
products.
31. While using the machine, the stopper/security valve must
never be removed. At the end of the usage it is necessary to
unscrew with caution the security valve (one turn) to remove
pressure from the boiler.
32.
Never remove security and protection devices.
33.
Before filling the boiler (manual loading models) unplug the
machine. Do not use distilled or demineralized water.
34. In case of anomalies while working (too noisy motor, not wor
-
king pump, excessive heating or other suspicious signals), turn
off the machine, unplug the power cable and see the chapter
”TROUBLESHOOTING”.
35.
In case of long periods of inactivity, unplug the machine, emp-
ty the boiler and keep the machine in a dry place.
36. Keep the packaging also for the eventual transport to the au
-
thorized technical assistance service.
BIEFFE IS NOT RESPONSBILE FOR DIRECT OR INDIRECT DAMAGES
TO PEOPLE, THINGS OR ANIMALS FOLLOWING THE DISREGARD
OF THE REQUIRENMENTS INCLUDED IN THIS MANUAL.
Summary of Contents for MAGIC VAPOR SANI BF009SANI
Page 2: ......
Page 18: ...18 MAGIC VAPOR SANI MAGIC VAPOR SANI BF009SANI ITALIANO 10 SCHEMA ELETTRICO...
Page 19: ...19 MAGIC VAPOR SANI ITALIANO 11 ESPLOSO...
Page 20: ......
Page 35: ...35 MAGIC VAPOR SANI MAGIC VAPOR SANI BF009SANI ENGLISH 10 WIRED DIAGRAM...
Page 36: ...36 MAGIC VAPOR SANI ENGLISH 11 EXPLODED VIEW...
Page 37: ......
Page 38: ......