47
FOREVER
ENGLISH
14. AUTOMATIC BOILER RECHARGE DIAGRAM
14.1 DIAGRAM
LEGENDA
A
BOILER PROBE +
RED
C
RELOADING HOSE –
BLACK
B
BOILER MASS –
BLACK
D
RELOADING HOSE +
RED
Tank
Electric board for
automatic refilling system
H probe
Boiler
MALFUNCTION
POSSIBLE CAUSES
SOLUTIONS
Continuous “beep”
Water shortage
Add water and bridge C
and D to ensure the correct
operation
Demineralized water
Add salt in water and bridge
C and D to ensure the correct
operation
Dirty contacts
Clean the contacts and
bridge C and D to ensure the
correct operation
Interrupted cord
Reconnect the cord and
bridge C and D to ensure the
correct operation
The recharging pump does
not stop
Probe H is dirty
Clean the probe and
disconnect the cable to verify
Cord F interrupted
Reconnect the cord F and
disconnect the cable to verify
Other causes
Replace the board and
disconnect the cable to verify
14.2 AUTOMATIC RELOAD SYSTEM TROUBLESHOOTING