![Biasi RIVA PLUS M90D.24S User Manual And Installation Instructions Download Page 23](http://html.mh-extra.com/html/biasi/riva-plus-m90d-24s/riva-plus-m90d-24s_user-manual-and-installation-instructions_2748987023.webp)
Technical information
17
Flue design
Flue pipe diameter
Coaxial
mm
60/100
Twin split pipes
mm
80
Roof
mm
80/125
Nominal heat flow rate*
kW
31,1
Exhaust temperature*
û
C
165
Smoke production*
kg/h
70,6
Flue gas figures
Nominal heat input*
kW
31,1
CO
2
content
%
6,3
O
2
content
%
9,7
CO content
ppm
<100
Exhaust temperature*
û
C
165
Other specifications
Height
mm
703
Width
mm
400
Depth
mm
325
Weight (dry)
kg
39
Water volume in the boler
(up to 1 bar)
l (kg)
1,1
* Values refer to tests with a 1 m chimney working at the nominal heat input