- 26 -
INST
ALL
ATION
TECHNICAL SPECIFICATIONS
4.6 Technical data M300V.1616 SV
(nom.Q.) Nominal heat input in
heating mode (Hi)
kW
17,0
kcal/h
14617
(nom.Q.) Nominal heat input in
d.h.w. mode (Hi)
kW
17,0
kcal/h
14617
(nom.Q.) Minimum heat input (Hi)
kW
3
kcal/h
2580
* Max. heat input in heating mode
60°/80°C
kW
16,7
kcal/h
14359
* Max. heat input in d.h.w. mode
60°/80°C
kW
16,7
kcal/h
14359
* Min. heat input 60°/80°C
kW
2,8
kcal/h
2408
** Max. heat input in heating mode
30°/50°C
kW
18,4
kcal/h
15821
** Max. heat input in d.h.w. mode
30°/50°C
kW
18,4
kcal/h
15821
** Min. heat input 30°/50°C
kW
3,2
kcal/h
2752
Data in heating mode
NOx class
6
Weighted NOx ***
mg/kWh
40
ppm
23
Weighted CO EN483 (0% O2)
ppm
n.a.
CO at nom. Q. (0% O2) ***
ppm
220,0
CO at nom. Q. (0% O2) ***
ppm
2,0
CO2 at nom. Q. with G20
%
8,5 - 9,5
CO2 at min. Q. with G20
%
8,5 - 9,5
CO2 at nom. Q. with G31
%
9,6 - 10,6
CO2 at min. Q. with G31
%
9,5 - 10,5
** Condensate quantity at nom.Q.
30°/50°C
l/h
2,7
** Condensate quantity at min.Q.
30°/50°C
l/h
0,5
Condensate pH
pH
4,0
Data in d.h.w. mode
CO2 at nom. Q. with G20
%
8,5 - 9,5
CO2 at min. Q. with G20
%
8,5 - 9,5
CO2 at nom. Q. with G31
%
9,6 - 10,6
CO2 at min. Q. with G31
%
9,5 - 10,5
* With return water temperature that does not permit
condensation
** With return water temperature that does permits
condensation
*** With coax. flue gas discharge 60/100 0.9 m and
METHANE gas G20
Measured efficiency in heating mode
* Nominal efficiency 60°/80°C
%
98,1
* Min. efficiency 60°/80 C
%
94,0
** Nominal efficiency 30°/50°C
%
108,4
** Min. efficiency 30°/50°C
%
105,2
* Efficiency At 30 % of load
%
n.a.
** Efficiency At 30 % of load
%
109,7
Heat loss at the chimney with
burner operating
Pf (%)
1,5
Heat loss at the chimney with
burner off ΔT 50°C
Pfbs (%)
0,2
Heat loss towards the environment
through the casing with the burner
operating
Pd (%)
0,4
Energy efficiency
* * * *
Gas supply pressures
Gas
Pa
mbar
Methane G20
Nom.
2000
20
Min.
1700
17
Max.
2500
25
Propane G31
Nom.
3700
37
Min.
2500
25
Max.
4500
45