background image

TTS-1e / TTS-1nce Front 

 

TTS-1e / TTS-1nce Front Panel 

The Unit features one power indication LED on the front panel: 

 

Not illuminated:

 The device is not powered. 

 

Flashing green:

 The unit is receiving power but not data, or the unit has not been configured 

correctly. 

 

Solid green:

 The unit is operational. Power supply and network traffic are functional. 

Summary of Contents for Vocia TTS-1e

Page 1: ...TTS 1e TTS 1nce OPERATION MANUAL 0D 585 0395 90A ...

Page 2: ...with a Vocia Message Server 1 MS 1e to enable text to speech messaging as part of a Vocia system solution The TTS 1e and TTS 1nce use Ethernet based control protocols in conjunction with Cobranet to function within a Biamp Vocia system and constructs announcements using a set of user defined templates ...

Page 3: ...1 75 inch 44 45 mm high and 19 inch wide rack space with 17 inch 432 mm depth Mounting the unit using four screws with washers will prevent marring of the front panel PVC or nylon washers are appropriate The unit should also be supported at the rear to prevent bending of the enclosure and or rack ears When installing the rack ears please note that the hardware is not symmetrical Please install the...

Page 4: ...ne power indication LED on the front panel Not illuminated The device is not powered Flashing green The unit is receiving power but not data or the unit has not been configured correctly Solid green The unit is operational Power supply and network traffic are functional ...

Page 5: ...3 Network Connection The TTS 1e TTS 1nce has four RJ45 Ethernet connectors located on the rear panel Control CobraNet Spare and Spare Each connector has two green LEDs which display Ethernet Link left LED and Activity right LED The TTS 1 TTS 1nce does not display the status of the CobraNet conductor LAN 1 Connector Control This port connects the TTS 1e TTS 1nce to a control network This should be ...

Page 6: ...ing World The Factory Default Device ID is 01 A Device ID of 00 is invalid and cannot be used To assign a Device ID of hex 07 leave the MSB switch on 0 and turn the LSB switch to 7 Device ID switches should be set using a 0 1 inch 2 5mm to 0 12 inch 3 0mm flat blade screwdriver More information on setting IDs and the hexadecimal numbering scheme can be found in the Vocia Help File NOTE Changes mad...