NOTE: The Qt100 control module does not have contact closure capabilities.

Input

Intended Source

Muted Upon Contact Closure

Input A

Paging

No

Input B

Background Music

Yes

An Important Note on Paging Signals

It is important to pay attention to the control module’s audio input requirements when implementing paging with your
sound masking system. All Qt control modules require a dry line-level signal from the paging source. The specification
for a nominal pro audio line-level signal is +4 dBu, 1.228 (Vrms), 1.737 (Vpk). However, Qt control modules can handle
signals that range from 1/2 to 2 times pro audio line levels. “Dry” emphasizes that the module’s paging inputs are not
telephone interfaces and must never see dial tone, ring voltage, battery current, etc.. This means that a typical FXO/FXS
output is NOT directly compatible and requires the use of a third-party paging controller.

Connecting an Input

Be sure to power off the control module by unplugging the power cord from the wall outlet. Use the diagrams below to
connect the cables from your audio input to the back of the control module. For the Qt 100, you will need to remove the
plastic backing. For the Qt 300/600, you will need to flip the control module down in the housing to access the inputs.
Inputs A and B are clearly labeled on the PCB of the Qt 300/600.

Balanced Audio Inputs

Connect the corresponding signal wires to the “+” and “-” ports on the control module’s input.

Unbalanced Audio Inputs

Mono Signals

Connect the signal wire to both the “L” and “R” ports on the module’s input.