background image

 

APPLICATIONS 

 
 

PAGE/MUSIC SYSTEM with REMOTE CONTROL 

 

FU

SE

FU

SE

O

2

1

1

2

outputs

level

signal / peak

signal / peak

level

input

input

4

3

3

4

outputs

level

signal / peak

signal / peak

level

input

input

6

5

Class 2 Wiring

5

6

outputs

level

signal / peak

signal / peak

level

input

input

8

7

7

8

outputs

remote control

level

CAUTION:
Risk of fire - 
replace fuse only
with same type
F 10 A H 250 V

115V

~

50/60Hz
900 Watts

signal / peak

signal / peak

level

input

input

MCA 8050

BIAMP SYSTEMS

an affiliate of Rauland Borg Corp.

MADE IN U.S.A.

HPF

HPF

OFF

OFF

OFF

BRIDGE

HPF

HPF

OFF

OFF

OFF

BRIDGE

HPF

HPF

OFF

OFF

OFF

BRIDGE

HPF

HPF

OFF

OFF

OFF

BRIDGE

CAUTION

RISK OF ELECTRICAL SHOCK.

DO NOT OPEN.

COMMERCIAL

AUDIO

EQUIPMENT

E158021

52SJ

UL

R

LISTED

C

US

50/60 Hz

~

27V

12 watts

class 2 wiring

logic inputs

logic inputs

output 8

output 7

output 6

output 5

output 4

output 3

output 2

output 1

CH 1

+10

trim

pad

+10

trim

CH 1

phantom

invert logic

phantom

invert logic

CH 2

level

level

level

level

level

level

level

level

pad

CH 2

DA28R

BIAMP SYSTEMS

Portland, Oregon

an affiliate of Rauland-Borg Corp.

INPUTS

OUTPUTS

optional

25/70/100V

transformers

(use HPF)

MCA 8050

2:50

1

COMPACT

DIGITAL AUDIO

DA28R

zone paging switches

optional music

assign switches

background music source

paging
microphone

channel 2 set for
page-over-music

zone 8

speakers

zone 7

speakers

zone 6

speakers

zone 5

speakers

zone 4
speakers

zone 3
speakers

zone 2
speakers

zone 1
speakers

WMC

 Control Panel

RDP

 Display Panel

MUTE

VOL   

VOL   

1

2

3

4

MUTE

VOL   

VOL   

MUTE

VOL   

VOL   

MUTE

VOL   

VOL   

SELECT

MUTE

VOL   

VOL   

MUTE

VOL   

VOL   

MUTE

VOL   

VOL   

MUTE

VOL   

VOL   

5

6

7

8

MASTER

DRI

15 watts

class 2 wiring

50/60 Hz

~

27V

gnd

IR2

IR3

19200

9600

2400

last

2

1

4

8

16

32

logic inputs

baud rate

remote

link port

serial port

device #

DC out

control voltage

outputs

remote
display

MADE IN U.S.A.

BIAMP SYSTEMS

 Portland, Oregon

an affiliate of 

Rauland-Borg Corp.

IR receiver

DRC 4+4 Remote Display Panel

1

2

3

4

preset

1

2

3

4

5

6

7

8

mute

mute

mute

mute

mute

mute

mute

mute

RDC

mEQ152

gain

16K

10K

6.3K

4K

1.6K

1K

630

400

250

160

100

63

40

25

16K

10K

6.3K

4K

2.5K

1.6K

1K

630

400

250

160

100

63

40

25

1

2

Channel 2

Channel 1

0

-12

+12

0

cut

boost

2.5K

2.5K

peak

out

in

12dB

6dB

on

peak

out

in

12dB

6dB

micro Equalizer

ADVANTAGE mEQ152

EQ

EQ

mEQ152

gain

16K

10K

6.3K

4K

1.6K

1K

630

400

250

160

100

63

40

25

16K

10K

6.3K

4K

2.5K

1.6K

1K

630

400

250

160

100

63

40

25

1

2

Channel 2

Channel 1

0

-12

+12

0

cut

boost

2.5K

2.5K

peak

out

in

12dB

6dB

on

peak

out

in

12dB

6dB

micro Equalizer

ADVANTAGE mEQ152

EQ

EQ

mEQ152

gain

16K

10K

6.3K

4K

1.6K

1K

630

400

250

160

100

63

40

25

16K

10K

6.3K

4K

2.5K

1.6K

1K

630

400

250

160

100

63

40

25

1

2

Channel 2

Channel 1

0

-12

+12

0

cut

boost

2.5K

2.5K

peak

out

in

12dB

6dB

on

peak

out

in

12dB

6dB

micro Equalizer

ADVANTAGE mEQ152

EQ

EQ

mEQ152

gain

16K

10K

6.3K

4K

1.6K

1K

630

400

250

160

100

63

40

25

16K

10K

6.3K

4K

2.5K

1.6K

1K

630

400

250

160

100

63

40

25

1

2

Channel 2

Channel 1

0

-12

+12

0

cut

boost

2.5K

2.5K

peak

out

in

12dB

6dB

on

peak

out

in

12dB

6dB

micro Equalizer

ADVANTAGE mEQ152

EQ

EQ

 

Summary of Contents for MCA 8050

Page 1: ...TM MCA Series Multi Channel Amplifiers Operation Manual Biamp Systems 10074 S W Arctic Drive Beaverton Oregon 97005 U S A 503 641 7287 www biamp com an affiliate of Rauland Borg Corp...

Page 2: ...print update June 17 2002 blank...

Page 3: ...Series amplifiers are covered by Biamp Systems five year warranty MCA Series features include 8 channels of 50W MCA 8050 or 150W MCA 8150 channels may be bridged in pairs for combined power terminals...

Page 4: ...uding amplifiers that produce heat Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two...

Page 5: ...an LED is green that channel has signal above 30dB When an LED is red that channel signal is clipping max power CAUTION Signal levels should be adjusted to avoid clipping Clipping can cause severe dis...

Page 6: ...R LISTED C US CAUTION Risk of fire replace fuse only with same type T 4 A L 250 V 230V 50 60Hz 900 Watts MCA 8150 115VAC rear panel F U S E F U S E O level signal peak signal peak level level signal p...

Page 7: ...nnels to Bridge together in pairs for a higher combined output power see Bridging on pg 6 Bridge disables the even numbered input and applies the odd numbered input signal to both amplifier channels F...

Page 8: ...vides 10V and ground terminals for use with potentiometers but external ramp voltage devices such as a BIAMP DRI may be used instead see Applications on pg 8 Potentiometers should be 25k linear taper...

Page 9: ...LECTRICAL SHOCK DO NOT OPEN COMMERCIAL AUDIO EQUIPMENT E158021 52SJ UL R LISTED C US 50 60 Hz 27 watts class 2 wiring 27V link port link serial port logic inputs logic outputs 1 2 3 4 5 6 7 override L...

Page 10: ...1 speakers WMC Control Panel RDP Display Panel MUTE VOL VOL 1 2 3 4 MUTE VOL VOL MUTE VOL VOL MUTE VOL VOL SELECT MUTE VOL VOL MUTE VOL VOL MUTE VOL VOL MUTE VOL VOL 5 6 7 8 MASTER DRI 15 watts class...

Page 11: ...9...

Page 12: ...d power 0 2 0 2 Intermodulation Distortion SMPTE 0 35 0 35 Frequency Response 20Hz 20kHz 0 1dB 0 1dB Input Impedance balanced unbalanced 20k ohms 10k ohms 20k ohms 10k ohms Input Sensitivity 0 775 Vrm...

Page 13: ...fans electrolytic capacitors and the normal wear and tear of appearance items such as paint knobs handles and covers are not covered under this warranty 4 BIAMP SYSTEMS SHALL NOT IN ANY EVENT BE LIABL...

Page 14: ...ed cabling must be used for system connections The apparatus is deemed incapable of producing harmonic emissions or flicker levels sufficient enough to interfere with other apparatus as noted in EN610...

Page 15: ...ed cabling must be used for system connections The apparatus is deemed incapable of producing harmonic emissions or flicker levels sufficient enough to interfere with other apparatus as noted in EN610...

Page 16: ......

Page 17: ......

Page 18: ......

Reviews: