MCA Series 

Multi-Channel Amplifiers 

 

Operation Manual 

 
 

Biamp Systems, 10074 S.W. Arctic Drive, Beaverton, Oregon 97005 U.S.A.        (503) 641-7287        www.biamp.com 

an affiliate of Rauland Borg Corp.

Summary of Contents for MCA 8050

Page 1: ...TM MCA Series Multi Channel Amplifiers Operation Manual Biamp Systems 10074 S W Arctic Drive Beaverton Oregon 97005 U S A 503 641 7287 www biamp com an affiliate of Rauland Borg Corp...

Page 2: ...print update June 17 2002 blank...

Page 3: ...Series amplifiers are covered by Biamp Systems five year warranty MCA Series features include 8 channels of 50W MCA 8050 or 150W MCA 8150 channels may be bridged in pairs for combined power terminals...

Page 4: ...uding amplifiers that produce heat Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two...

Page 5: ...an LED is green that channel has signal above 30dB When an LED is red that channel signal is clipping max power CAUTION Signal levels should be adjusted to avoid clipping Clipping can cause severe dis...

Page 6: ...R LISTED C US CAUTION Risk of fire replace fuse only with same type T 4 A L 250 V 230V 50 60Hz 900 Watts MCA 8150 115VAC rear panel F U S E F U S E O level signal peak signal peak level level signal p...

Page 7: ...nnels to Bridge together in pairs for a higher combined output power see Bridging on pg 6 Bridge disables the even numbered input and applies the odd numbered input signal to both amplifier channels F...

Page 8: ...vides 10V and ground terminals for use with potentiometers but external ramp voltage devices such as a BIAMP DRI may be used instead see Applications on pg 8 Potentiometers should be 25k linear taper...

Page 9: ...LECTRICAL SHOCK DO NOT OPEN COMMERCIAL AUDIO EQUIPMENT E158021 52SJ UL R LISTED C US 50 60 Hz 27 watts class 2 wiring 27V link port link serial port logic inputs logic outputs 1 2 3 4 5 6 7 override L...

Page 10: ...1 speakers WMC Control Panel RDP Display Panel MUTE VOL VOL 1 2 3 4 MUTE VOL VOL MUTE VOL VOL MUTE VOL VOL SELECT MUTE VOL VOL MUTE VOL VOL MUTE VOL VOL MUTE VOL VOL 5 6 7 8 MASTER DRI 15 watts class...

Page 11: ...9...

Page 12: ...d power 0 2 0 2 Intermodulation Distortion SMPTE 0 35 0 35 Frequency Response 20Hz 20kHz 0 1dB 0 1dB Input Impedance balanced unbalanced 20k ohms 10k ohms 20k ohms 10k ohms Input Sensitivity 0 775 Vrm...

Page 13: ...fans electrolytic capacitors and the normal wear and tear of appearance items such as paint knobs handles and covers are not covered under this warranty 4 BIAMP SYSTEMS SHALL NOT IN ANY EVENT BE LIABL...

Page 14: ...ed cabling must be used for system connections The apparatus is deemed incapable of producing harmonic emissions or flicker levels sufficient enough to interfere with other apparatus as noted in EN610...

Page 15: ...ed cabling must be used for system connections The apparatus is deemed incapable of producing harmonic emissions or flicker levels sufficient enough to interfere with other apparatus as noted in EN610...

Page 16: ......

Page 17: ......

Page 18: ......