background image

I SERIES                                                               IV6-SB-AF Instructions   

 

                                        Page 5 

SUB BEHIND ARRAY FRAME 

(CONTINUED)

SB-3.

  Loosely connect the splay brackets to the array frame

SB-4.

  Attach Lift Point to carriage hang point

3

2

4

SB-2.

 Loosen nuts in the direction the carriage has to go, move carriage to 

designated position, and tighten hardware

HN-F

HHB-F

Hardware

(hex nuts, flat washers)

Locking 

ring

C-HN

C-HB

PY1-EN750-1550

ASSEMBLY 

(continued)

2.

 Move the carriage to the suggested 

hang point  distance so that the frame 

will hang level under load. 

Refer to the 

Sub-behind hang point calculator. 

(IV6 

Downloads)

 The hang point distance is 

measured from the front of the frame to 

the lift hole in the carriage. 

3.

  Using  the  10.9  flanged  bolts  and 

nuts, loosely attach the S1 brackets to 

the  array  frame  with  the  Community 

name facing out.

4.

  If  using  the  PY1-EN750-1550  lift 

point, attach it to the carriage with the 

included carriage hex bolt and secure 

with the hex nut and locking ring. 

Final Step.

 After the carriage is 

in  its  final  position  (and  the 

system is aimed), 

one at a time

loosen each hex nut securing the 

carriage  a few threads, apply a drop of 

red thread-locking compound, and re-

tighten the nut. Repeat for each of the 4 

hex nuts securing the carriage on the 

threaded  rods.  This  will  help  prevent 

movement of the carriage over time.

Summary of Contents for IV6-SB-AF

Page 1: ...omplete set of instructions including all of the IV6 indoor rigging frames accessories and information is available on the Biamp website here IMPORTANT The Instructions and illustrations in this manua...

Page 2: ...t after it has been removed from the packaging as damage could occur during shipping Please note that once the shipment has left your dealer or the Biamp factory the responsibility for damage is alway...

Page 3: ...he VenuePolar module Loads tab automatically populates and updates in real time as an array is built and aimed Refer to the IV6 System Design and Installation Manual for instructions and explanations...

Page 4: ...array can be rotated up to 90 to prevent the cabinets from potentially hitting while lifting the assembly and adding to the length of the array 1 Parts SB AF IV6 SB AF SB AF Sub Behind Array Frame 1...

Page 5: ...ator IV6 Downloads The hang point distance is measured from the front of the frame to the lift hole in the carriage 3 Using the 10 9 flanged bolts and nuts loosely attach the S1 brackets to the array...

Page 6: ...in the IV6Manuals and Tools All under the Manuals tab on the website here 1 Retrieve the weight of the main array from Line 0 of the Loads tab in EASE Focus 3 EF3 or from section 5 1 of the EF3 projec...

Page 7: ...PCS 3 00 76 2 11 45 290 8 3 25 82 6 37 9 5 25 6 3 3 61 91 8 26 69 677 9 62 25 1581 2 4 12 104 6 24 74 628 3 7 70 195 6 1 50 38 1 1 25 31 7 2 50 63 5 9 01 228 9 1 19 30 2 4 00 101 6 3 00 76 2 40 83 10...

Page 8: ...manual was complete and accurate when printed However due to ongoing technical advances changes or modifications may have occurred that are not covered in this manual The latest version is available...