background image

Page 9

n

o

i

t

p

i

r

c

s

e

D

n

o

i

t

a

u

n

e

t

t

A

e

s

i

o

N

e

t

i

h

W

B

d

1

1

1

l

e

v

e

L

B

d

3

1

2

l

e

v

e

L

B

d

9

1

3

l

e

v

e

L

B

d

5

3

4

l

e

v

e

L

n

o

i

t

c

u

d

e

r

e

n

o

T

B

d

5

1

l

e

v

e

L

B

d

8

2

l

e

v

e

L

B

d

1

2

3

l

e

v

e

L

B

d

5

6

4

l

e

v

e

L

e

g

a

t

l

o

V

c

d

V

5

1

-

5

n

o

i

t

p

m

u

s

n

o

c

t

n

e

r

r

u

C

A

m

5

4

e

z

i

s

B

C

P

m

m

7

3

x

6

2

Sound Engineering Solutions

4.

Demonstration mode.

The NEDSP1061 module features 2 preset demonstration modes. These demonstrate
the noise cancellation abilities of the NEDSP1061 module.

Demonstration 1:
Hold down the button and switch on the FT-817. After a short time the unit will emit a 2
tone beep. Release the button. The unit is now in demonstration mode 1.
The module will switch the noise cancellation on for 1.5 seconds, then off for 1.5 seconds.
It will then move onto the next level and repeat this continuously through all 4 levels.
This mode is particularly effective when the FT-817 is just receiving static, as it demonstrates
the attenuation of white noise at all the levels.
Alternatively tune the FT-817 into a good quality FM speech broadcast. This demonstration
shows how little the DSP alters the speech, at any of the levels.

Demonstration 2:
Follow the procedure as above. Wait for the second 2 tone beep, then release the key.

In this mode the filter level is set to level 3.

The noise cancellation is switched on for 3 seconds, then off for 3 seconds. This loops
until the user aborts this mode.
This is a good demonstration for listening noisy SSB conversations showing the before
and after.

Exiting the demonstration mode.
Hold down the button until the 2 tone beep is heard. Release the button.
After a short delay the LED will flash indicating the stored level, as during the normal
switch on.

5.

Notes about the noise reduction.

When using the module on level 4 the speech may sound slightly distorted when high
levels of noise are present.

6.

Specifications.

Summary of Contents for NEDSP1061

Page 1: ...Page 1 bhi NEDSP1061 Noise Reduction Module Yaesu FT 817 Version Fitting Instructions 1061 104D Issue B Sound Engineering Solutions bhi ...

Page 2: ...dB level 4 65dB Current consumption 45mA The fitting of the bhi NEDSP1061 module involves the removal of small surface mount components and the drilling out of the transceivers lid This should only be carried out by a qualified engineer bhi accepts no responsibility for the fitting or installation of the NEDSP1061 module and are not liable for any damage to equipment caused by its fitment All atte...

Page 3: ...ibbon cable Hinge the main unit forward over the front unit ribbon cable To place the module into the audio path it is necessary to remove the audio signal coupling capacitor C1338 The following diagram shows the position of the component Carefully remove the capacitor Connect the screened lead from the NEDSP1061 module as follows Red lead to R1482 side of C1338 audio in Blue lead to the other sid...

Page 4: ... Screen Blue wire Red wire NEDSP1061 screened lead connection detail Q1084 Q1057 R1482 Lower side of main unit Location of C1338 on lower side of main unit Location of Q1082 TP1084 on upper side of main unit ...

Page 5: ...itions The preferred position is in the location of the optional filter This provides the more mechanically secure location If the optional filter is or is going to be installed the module can be installed along side the filter Solder the red power lead to the drain of Q1082 TP1084 Connect M3 ring tag 0V leads using the right front screw Affix the NEDSP1061 module using the supplied self adhesive ...

Page 6: ...17 Connect an antenna Switch on P2 Input level P3 Beep volume P1 Output level NEDSP1061 controls 4 Adjustments Detune the FT 817 to receive static Press and release the DSP button the unit will beep to indicate which filter level is selected 1 beep for level 1 2 for level 2 etc The led will also flash in green at the same time The noise level will now be reduced Repeat this for all 4 filter levels...

Page 7: ...ng P2 Problem Increasing the volume to the FT 817 creates distortion Cause Output level from the NEDSP1061 is over driving the FT 817 power amplifier Reduce the output level using P1 Note When listening high noise signal broadcasts it is possible for the DSP to create an effect that resembles slight clipping Always check clipping problems with a good quality clean audio signal such as an FM talk s...

Page 8: ...s off When the noise cancellation level is changed the LED will flash green to indicate which level has been selected Simultaneously the DSP will beep to give audible indication of DSP level This allows the operator to change the DSP level without having to look at the LED to see which level has been selected A short beep is emitted to acknowledge a button press The module will store the current D...

Page 9: ...ontinuously through all 4 levels This mode is particularly effective when the FT 817 is just receiving static as it demonstrates the attenuation of white noise at all the levels Alternatively tune the FT 817 into a good quality FM speech broadcast This demonstration shows how little the DSP alters the speech at any of the levels Demonstration 2 Follow the procedure as above Wait for the second 2 t...

Page 10: ...Page 10 bhi Ltd P O Box 136 Bexhill on Sea East Sussex TN39 3WD email sales bhi ltd co uk www bhi ltd co uk Tel 0870 240 7258 Fax 0870 2407259 ...

Reviews: