19
Technical data
Unit
measure
SM 500 Z
SM 500 /
400 V
Max log capacity (length)
mm
1070
1070
Max log diameter
mm
300
300
Splitting force
t
9
9
Max operating pressure
bar
235
235
Max PTO (shaft) speed
RPM
540
under permanent load
RPM
420
Motor power P1
kW
4,0
Rated current
A
6,8
Motor speed
RPM
2845
Rated voltage
V
400
Domestic overload safety
A
16 line prot. fuse
Out-to-out transport length
mm
1870
1870
Length with extension table
mm
3400
3400
Height
mm
1200
1200
Width
mm
700
700
Weight
kg
310
330
Oil tank capacity
l
30
30
* The actual splitting force may vary ± 10% of the nominal rating.
9. TECHNICAL DATA
9.1 Noise level & emissions
Noise emissions were measured in accordance with the European di-
rectives for the measurement of noise emissions on the workplace.
The measurement was performed by external authorized certifi cation
bodies in compliance with the applicable standards based on applica-
ble rules for agricultural and forestry equipment.
Noise levels were detected and measured 1600mm high above the
machine and 1000mm away in front of it. The detected noise level
was:
LpA = 80 dB(A)