1.2.9. Animals are to be kept at a safe distance away from the generator.
1.2.10. Unplug the generator at all times during downtime.
1.2.11. Thermostat control allows the generator to be turned on at any time.
1.2.12. The generator must not be used in frequently visited rooms and in
bedrooms.
1.2.13. Do not obstruct the airflow (back of the device) and air intake (front) of the
generator.
1.2.14. If the generator is plugged in, hot, or currently running, it must not be
moved, manipulated, refueled or attempt maintenance work of any kind.
1.2.15. Do not channel the air flow at intake or the generator output.
1.2.16. Keep the safe distance between the hot parts of the generator and
thermos-sensitive or combustible materials(including feeder cable).
1.2.17. If the supply cord is damaged, it must be replaced by the manufacturer,or
similarly qualified persons in order to avoid a hazard
1.2.18.heater is not located immediately below a socket-outlet
1.2.19. Do not use the heater with a programmer, timer or any other device that
switches the heater on automatically;
【
2.FUEL
】
▲ WARNING: The generator only runs on automotive DIESE fuel.
To avoid fire or explosion, use only automotive diesel fuel. Do not use gasoline,
naphtha, paint thinners, alcohol, kerosene or any other combustible liquids.
For low-temperature operation, use antifreeze supplements.
【
3.OPERATING PRINCIPLE
】
See fig.NO1
Airflow is necessary to ensure proper combustion, it is supplied by the internal burner
fan. The air enters the burner funnel and gets mixed with a high-pressure fuel jet. The
fuel flow is secured by an electrical pump, which sucks the fuel away from the tank and
moves it to the nozzle under high pressure.
【
4.OPERATION
】
Summary of Contents for BGO1402-20
Page 3: ...FIGURES NO 1 B A A B NO 3 NO 2 C...
Page 13: ......