AUXILIARY OUTPUT CONNECTIONS
Fig. N
9.3)
CONNECTING DETECTORS/SAFETY SENSORS WITH TESTING DURING
OPENING AND CLOSING
Fig. P, Q
10)
ARM TYPE SELECTION
Fig. H
11) OPERATING PARAMETER MANAGEMENT - DIP SWITCH
DIP
SW Logic
Default
Cross out setting
used
Description
1
Arm type
OFF
OFF
Double lever
ON
Single lever
2
LOW ENERGY
OFF
OFF
Standard
ON
Low Energy *
3
PUSH & GO
OFF
OFF
Disabled
ON
Enabled **
4
KEY mode
OFF
OFF
Latching
ON
Non-latching
5
Actuator type
OFF
OFF
VISTA SW MXL
ON
ON
VISTA SW SXL
6
Operating mode 1
OFF
VISTA SW SXL: OFF
Motor-driven
closing
VISTA SW SXL: ON
Spring-oper-
ated closing
VISTA SW MXL***: OFF Continuous
operation
VISTA SW MXL***: ON Panic opening
7
Operating
mode 2
OFF
VISTA SW SXL****:
OFF
No reopen-
ing when
obstacle is
detected dur-
ing spring-
operated
closing
VISTA SW SXL****: ON
Reopening
when obsta-
cle is detected
during spring-
operated
closing
VISTA SW MXL*****:
OFF
No batteries
fitted
VISTA SW MXL*****:
ON
Batteries
fitted
8
Not used
OFF
* Reduced-speed opening with increased hold time (disabled hold time)
using the disabled opening command (on configurable output) [AUX IN 1, by
setting parameter 15=0 (“Operating parameter management-display” section)].
Subsequent closing is spring operated with obstacle management
** Moving the leaf manually while stationary in the closed position triggers its
automatic opening and closing.
*** Battery-powered panic mode
**** Motor-driven reopening in event of collision during spring-operated closing
****** Use of batteries
WARNING: confirm with RESET each DIP variation.