Rigel 6 common connections 

 

50  51  52 

70  71  72 

20  21 

11 

12 

14  15  16 

10 

22 

23  24 

25  26 

27  28 

29 

60  61  62  63  64  65 

73  74  75  76 

77  78  78 

M2 

M1 

Capacitor 

Capacitor 

8K2 resistive, 70-72 or 70-74, Logic 8 

51 

50 

51 

52 

Desme  

75 & 76 SAFE 3 = 004 
Photo cells, active closing only 

Ic Inputs 1,2,3,4, 

Mag Lock or 

CISA 

 

Summary of Contents for Rigel 6 QRG

Page 1: ...nings in the main instruction document first Always apply good safe state of the art engineering and electrical installation principles Safety of the completed installation is the ultimate responsibility of the installer This product is not suitable for DIY use and should only be installed and maintained by a trained skilled professional installer ...

Page 2: ...individual transmitters Ø Magnetic lock powered constantly during closing cycle Ø U Link Ø 6 safe inputs Safe 1 2 8K2 Ø Reset able low voltage fuse Ø Auto set for both Hydraulic Electro mechanical motors Ø Obstacle Detection electro mechanical motors ONLY Ø Gate open close buttons on control board Ø Error messages on cover lid and on control panel 30 errors ...

Page 3: ...Terminal Layout ...

Page 4: ...Rigel 5 to Rigel 6 terminal numbers ...

Page 5: ...Motor Connections Old Rigel 5 New Rigel 6 Motor 1 10 11 12 opens first followed by Motor 2 14 15 16 Motor 2 closes first followed by Motor 1 Capacitor is connected across motor winding M1 10 12 M2 14 16 ...

Page 6: ...0 21 11 12 14 15 16 10 22 23 24 25 26 27 28 29 60 61 62 63 64 65 73 74 75 76 77 78 78 M2 M1 Capacitor Capacitor 8K2 resistive 70 72 or 70 74 Logic 8 51 50 4 1 2 51 52 Desme 75 76 SAFE 3 004 Photo cells active closing only Ic Inputs 1 2 3 4 Mag Lock or CISA ...

Page 7: ...Menu System Quick Menu X 2 Rapidly Traditional Menu To enter the traditional Menu press the OK button twice rapidly Halt OK Follow user guide OK Para Logic Radio Default ...

Page 8: ...Quick Menu Layout This will provide a working system ...

Page 9: ...d mandatory for hydraulics except Lux FC Manual release and set limit switch positions Igea only Connect up the motor supply cables to the Blue connectors 10 11 12 14 15 16 Do NOT connect any accessories at this stage and leave all factory links fitted Position gates in the closed position Sub Lux P Series Kustos Igea Eli 250 leave in the factory set position Navigate to the Autoset menu and launc...

Page 10: ...en the closed position is reached press the OK button With showing press the OK button 3 2 1 motor 1 will open followed by motor 2 from the open position motor 2 will close first followed by motor 1 upon completion OK will be displayed If the motors try to close at the launch of the Autoset then the motor cables must be swapped 10 12 14 16 When a gate system is powered for the first time or after ...

Page 11: ...Time Clock Setting Clock for the day of the week Day of install i e Tuesday ...

Page 12: ... ie 08 00 First OFF ie10 20 Second ON ie 15 00 Second OFF ie 16 10 Programming in 10 min blocks 1 10 past the hour 2 20 past 3 30 past 4 40 past 5 50 past Example 1st ON 08 30 08 3 1st OFF 09 50 09 5 Set Chrono Time Bands in Logic to 1 for timer 2 for ped timer ...

Page 13: ...Radio Individual transmitters can be removed from any channel The location number within the radio channel must be known to carry out this function ...

Page 14: ...button on a Mitto into the 2nd radio channel Program Ic1 5 60 61 Aux Out 2 14 24 25 2ch 8 Wire between 24 61 25 60 How to open the Pedestrian leaf on the Third button on a Mitto 2 4 Code the Third button on a Mitto into the 3rd radio channel Program Ic2 4 60 62 Aux Out 3 0 3ch 4 Wire link between 26 62 27 60 ...

Page 15: ...Obstacle Sensitivity ...