type
50
30
SIMPLIFIED MENU
Exit Menù
Confirm/Switch on display
Scroll up
Scroll down
lh
PRESET
DEFAULT
ar
sr
ac
sc
ind
PARAMETERS
Automatic Closing Time
10
10
10
5
5
5
Opening motor torque
75
99
99
99
99
99
Closing motor torque
75
99
99
99
99
99
Speed during opening
99
99
99
99
99
99
Speed during closing
99
99
99
99
99
99
Slow-down distance
70
60
(MOOVI 30)
--------
70
(MOOVI 50)
60
(MOOVI 30)
--------
70
(MOOVI 50)
60
(MOOVI 30)
--------
70
(MOOVI 50)
60
(MOOVI 30)
--------
70
(MOOVI 50)
60
(MOOVI 30)
--------
70
(MOOVI 50)
Alarm time
30
60
60
30
30
30
Braking
2
2
2
2
2
2
Zone
0
0
0
0
0
0
Opening value calibration
80
80
80
80
80
80
Closing value calibration
25
25
25
25
25
25
Acceleration
3
3
3
3
3
3
LOGIC
Automatic Closing Time
ON
ON
OFF
ON
OFF
OFF
Block Pulses
ON
OFF
OFF
ON
ON
OFF
Impulse lock TCA
OFF
OFF
OFF
OFF
OFF
OFF
2 step
OFF
OFF
OFF
OFF
OFF
OFF
3 step
ON
ON
OFF
ON
OFF
OFF
Pre-alarm
OFF
OFF
OFF
ON
ON
OFF
Deadman
OFF
OFF
OFF
OFF
OFF
ON
Photocells
during opening
ON
ON
ON
ON
ON
OFF
Rapid closing
OFF
OFF
OFF
OFF
OFF
OFF
Photocell test
OFF
OFF
OFF
OFF
OFF
OFF
Master/slave
OFF
OFF
OFF
OFF
OFF
OFF
Fixed code
OFF
OFF
OFF
OFF
OFF
OFF
Remote control
programming
ON
ON
ON
ON
ON
ON
SCA Alarm
ON
ON
ON
OFF
OFF
ON
Reversing motion
OFF
OFF
(left)
--------
ON
(right)
OFF
(left)
--------
ON
(right)
OFF
(left)
--------
ON
(right)
OFF
(left)
--------
ON
(right)
OFF
(left)
--------
ON
(right)
Timer on open
OFF
OFF
OFF
ON
ON
OFF