3)  Fit post “F” and protection frame “G” as shown in Fig. 24B. The post 

is fastened from inside the barrier by means of 3 screws (supplied). 

4)  Fit the photocell to the post, as shown in the instruction sheet for Cel-

lula 130.

Refer to the instruction sheet for Cellula 130 for further information.

6.7) Moovi accessories: boom length limits and balancing (Fig.25)
6.7.1) Moovi 30RMM and Moovi 50RMM
All barriers belonging to the MOOVI series are equipped with a hooking 
bracket with 3 securing points located on the device for boom balancing 
(Fig. 25 - ref. A points A-B-C).
The ideal securing point for correct balancing of the boom must be 
chosen according to the barrier type and to the length of the boom and 
accessories installed.
Tab.1 of Fig.25 shows the weight expressed in kgs by linear meter (kg/m) 
for each accessory.
When the supporting leg Moovi GA/GAMA is used, it is necessary to 
calculate the arbitrary weight in Kg/m, using the following formula:

Kg/m = 1,2/L

where L stands for the length of the boom.
Then proceed as follows:
1) Sum up the total linear weight of the accessories installed (including 

boom weight).

2) Find the crossing point between the length of the boom and the total 

weight of the accessories on the diagram, making reference to the 
MOOVI model.

3) The point found in this way will indicate the correct hooking point (A-

B-C).

Example
MOOVI 50 with: 
(boom measuring 4,0m + BIR + GAMA +1PCA).
(1,028+0,510+(1,2/4,0)+0,160)= 1,97
The crossing point between value 1,97 and boom length equal to 4,0 is 
within the “A” area of MOOVI 50 graph. “A” hooking point will therefore 
be suitable for correct boom balancing.
Calibrate the spring as described in paragraph 7.
WARNING!:
The securing points marked with A and B can be used with MOOVI 
50RMM only.
The securing point marked with C can be used with MOOVI 30S/30RMM 
only.
If the point found is within the crossed area that means that installation 
is not possible and it is necessary to shorten the boom or reduce the 
number of accessories.

If no accessory is used, only use the weight of the “PA” boom to find the 

securing point.

6.7.2) Moovi 30S
For Moovi 30S model, observe the following:
Max. boom length: 

3m

Hooking point:   

C

Accessories that can be used without shortening the boom: BIR - PCA 
- Moovi Light
Accessories that cannot be usedGA/GAMA – SB

7) BAR BALANCING (Fig.9)

-   Activate the emergency release (fig.14).

-   Position the bar at about 45° (fig.9). The bar must remain still.

-   If the bar tends to open, unload the spring by operating on the “T” tie 

rod.

-   If the bar tends to close, load the spring by operating on the “T” tie rod.
-   In both cases, load or unload the spring until the bar remains still at 

about 45°.

-   Reset the motorised operation by rotating the release key to the op-

posite direction (fig.14).

WARNING! During the closing operation, the balancing spring must never 
be reduced to a pack (be totally compressed). Fig.9 indicates the position 
where the minimum value of the compressed spring is measured with the 
rod in the opening (vertical bar) position.

8) ELECTRICAL INSTALLATION SET-UP
WARNING: before opening the door, make sure that the spring has 
been unloaded (rod at 43°).

 Set up the electrical installation (fig. 10) with 

reference to the current regu-lations for electrical installations CEI64-8, 
IEC364, in conformity with HD384 and other national standards. Keep 

the mains power supply con-nections definitely separate from the service 

connections (photocells, elec-tric edges, control devices etc.). 
Warning! For connection to the mains, use a multipolar cable having 
minimum 3x1.5mm

2

 cross section and complying with the previously 

mentioned regulations (for example, if the cable is not protected, it 

INSTALLATION MANUAL

ENGLISH

must be at least equal to H07 RN-F, whereas if it is protected it must 
be at least equal to H07 VV-F with a 3x1.5 sq mm

2

 cross section). 

Connect the control and safety devices in conformity with the previously 
mentioned installation standards. Fig.10 shows the number of connections 
and section for a 100m length of power supply cables; for greater lengths, 
calculate the section for the true automation load. When the auxiliary 
connections exceed 50-metre lengths or go through critical disturbance 
areas, it is recommended to decouple the control and safety devices by 
means of suitable relays. 

The main automation components are (fig.10):

I)  

Type-approved adequately rated omnipolar circuit-breaker with 
at least 3,5 mm contact opening, provided with protection against 
overloads and short circuits, suitable for cutting out automation 
from the mains. Place, if not al ready installed, a type-approved 
differential switch with a 0.03A threshold just before the automa-
tion system. 

QR)  

Control panel and incorporated receiver.

S)  

Key selector.

AL)  

Blinker with tuned antenna.

M)  Actuators.
A)  

Bar.

F)  

Rest fork.

CS)  

Electric edge.

CC)  

Edge control.

Ft,Fr)   Pair of photocells.
CF)  

Photocell post.

T)  

1-2-4 channel transmitter.

RMM)   Inductive metal mass detector.
LOOP)  Mass detector loops.

9) LEO-MV-D CONTROL PANEL 
Power supply:  ............................................................ 220-230V 50/60Hz
Mains/low voltage insulation:  .................................... > 2MOhm 500V
Dielectric strength:  .................... mains/low voltage 3750V~ for 1 minute
Motor output current:  ................................................................ 1.5Amax
Maximum motor power: ................................................................. 750W
Supply to accessories: .................................. 24V~ (1A max absorption)
Gate-open warning light:  ........................................ 220-230V~ 3W max
Blinker: .................................................................. 220-230V~ 40W max
Dimensions:  .......................................................................

see figure 17

Fuses:..................................................................................see figure 18

10) TERMINAL BOARD CONNECTIONS (Fig.19)
WARNING –
 During the wiring and installation operations,  refer to the 
current standards as well as principles of good technical practice. 
The cables must be tied by additional fastening next to the terminals, by 
means of clips for example.

All the operator wiring operations must be carried out by qualified personnel.

JP1
1  

 GND terminal

2-3  

Single-phase mains supply 220-230V 50/60Hz (2=N) (3=L)

JP2
4-5 

Blinker connection (mains voltage) 40W Max.

6-7-8-9 

Motor connection: 

 

6   operation 1  + capacitor   

 

 

7   common  

(blue) 

 

8   operation 2  

 

9   capacitor 

JP3
10-11 

Output 24V~ 1A max – power supply for photocells or other 
devices.

12-13 

Gate-open warning light output (24V 3W max)  

JP4   

 

Barrier status output

20-18  

 

Closed Contact with barrier raised

20-19  

 

Closed Contact with barrier lowered

Contact switching for barrier status control. 
To be used in Parky systems.
JP5 

Encoder connection

 

WARNING! The maximum length of the connection cable of 
the encoder should not exceed 3.00 mt.

JP8
21-22 

Open-Close button (N.O. Start), key selector.

21-23 

Block button (N.C. Stop). If not used, leave jumped.

21-24 

Photocell input (N.C.). If not used, leave jumped.

21-25 

Opening limit switch connection (N.C. SWO). If not used, 
leave jumped.

21-26 

Closing limit switch connection (N.C. SWC). If not used, leave 
jumped.

MOOVI 30S-30RMM-50RMM  Ver. 06 -

 19

D81

1480_07

Summary of Contents for MOOVI 30S

Page 1: ...E FOR VEHICULAR BARRIERS AUTOMATISME ELECTROMECANIQUE POUR BARRIERE POUR VÉHICULES ELEKTROMECHANISCHER ANTRIEB FÜR FAHRZEUGSCHRANKEN AUTOMATISMOS ELECTROMECANICOS PARA BARRÉRAS VEHICULAR AUTOMATIZAÇÃO ELECTROMECÂNICA PARA BARREIRA VEICULAR 8 027908 283818 ISTRUZIONI D USO E DI INSTALLAZIONE INSTALLATION AND USER S MANUAL INSTRUCTIONS D UTILISATION ET D INSTALLATION INSTALLATIONS UND GEBRAUCHSANLEI...

Page 2: ...2 MOOVI 30S 30RMM 50RMM Ver 06 D811480_07 ...

Page 3: ...s must not walk within the operator manoeuvring area An appropriate pedestrian passageway must be provided for 2 EMERGENCY RELEASE Fig 1 The emergency release allows the bar to be manoeuvred manually It is activated from the outside of the box by inserting the personalised key into the lock placed under the bar and rotating it anticlockwise by 180 WARNING When an actuator without bar needs to be r...

Page 4: ... which might occur during use The installation must comply with the provisions set out by the follow ing European Directives 89 336 CEE 73 23 EEC 98 37 EEC and subsequent amendments Disconnect the electrical power supply before carrying out any work on the installation Also disconnect any buffer batteries if fitted Fit an omnipolar or magnetothermal switch on the mains power supply having a contac...

Page 5: ...n it into the correct posi tion F Tighten the tie rod fig 4 ref 5 blocking the lever fig 4 ref 6 by means of a torque wrench set at about 80 N m G Bring the release key fig 6 to the manual operation position and manually rotate the lever fig 4 ref 6 downwards by 90 fig 7 so as to bring the barrier to the right hand opening position H Lock the spring stretcher fig 4 ref 2 into position fig 4 ref Dx...

Page 6: ...cal installations CEI64 8 IEC364 in conformity with HD384 and other national standards Keep the mains power supply con nections definitely separate from the service connections photocells elec tric edges control devices etc Warning For connection to the mains use a multipolar cable having minimum3x1 5mm2 crosssectionandcomplyingwiththepreviously mentioned regulations for example if the cable is no...

Page 7: ...Alarm time alarm time 30s In the case of obstacle detection or photocell engagement at the end of the time set ranging from 10s to 240s the SCA contact is closed The contact is subsequently opened by the STOP command or by triggering of the closing limit switch Only active when the SCA Alarm logic is set to OFF 4 Zone zone 0 Set the zone number between a minimum value of 0 and a maximum value of 1...

Page 8: ...ween terminals 19 and 20 with barrier lowered contact closed between terminals 18 and 20 with barrier raised 14 SERIAL CONNECTION USING SCS1 BOARD Fig 21 The LEO MV D control panel allows several automation units SCS1 to be connected in a centralised way by means of appropriate serial inputs and outputs This makes it possible to use one single command to open and close all the automation units con...

Page 9: ...by type electrical components copper aluminium plastic etc 21 DISMANTLING WARNING before opening the door make sure that the spring has beenunloaded rodat43 Whentheautomationsystemisdisassembled to be reassembled on another site proceed as follows Disconnect the power supply and the entire electrical installation Remove the actuator from its fixing base Disassemble all the installation components ...

Page 10: ...MOOVI 30S 30RMM 50RMM Ver 06 23 D811480_07 ...

Page 11: ...24 MOOVI 30S 30RMM 50RMM Ver 06 D811480_07 ...

Page 12: ...Fig 3 Fig 1 Fig 2 500 600 400 500 20 350 400 22 cm 38mm 5m Moovi 50 RMM 3m Moovi 30S RMM 6m Moovi 50 RMM ATG 6 32 cm 80 cm 70mm 100 cm 7 10 4 8 9 5 11 6 MOOVI 30S 30RMM 50RMM Ver 06 57 D811480_07 ...

Page 13: ...Fig 7 Fig 5 Fig 6 Fig 4 1 2 6 3 SX DX 80Nm 4 5 58 MOOVI 30S 30RMM 50RMM Ver 06 D811480_07 ...

Page 14: ...MOOVI 30S 30RMM 50RMM Ver 06 59 D811480_07 ...

Page 15: ...Fig 13 Fig 14 2 G C Fig 11 Fig 12 SWC SWO SWC SWO 60 MOOVI 30S 30RMM 50RMM Ver 06 D811480_07 ...

Page 16: ...VI130 MOOVI PCA MOOVI LIGHT PRM 2 3 7 8 P L P D C D C 6 4 SX 2 5 DX 1 2 Left Gauche Links Izquierda Esquerda 1 Right Droite Rechts Derecha Direita GTO ATG GTO AQG ATG 3 ATG 5 ATG 6 ELL 3 5 AQG 3 AQG 5 MOOVI 30S 30RMM 50RMM Ver 06 61 D811480_07 ...

Page 17: ...62 MOOVI 30S 30RMM 50RMM Ver 06 D811480_07 ...

Page 18: ...MOOVI 30S 30RMM 50RMM Ver 06 63 D811480_07 ...

Page 19: ...64 MOOVI 30S 30RMM 50RMM Ver 06 D811480_07 ...

Page 20: ...30 A CELLULA130 B MOOVI130 F G Montaggio lampeggiante Assembling the flashing light Montage du clignotant Montage Blinkleuchte Montaje luz intermitente Montagem da lâmpada cintilante V1 V2 1 2 1 32 4 8 13 5 3 9 25 3 9 V3 5 4 3 V2 V1 V3 4 2 3 V1 V2 MOOVI 30S 30RMM 50RMM Ver 06 65 D811480_07 ...

Page 21: ...3 5 m 3 9 m 4 m 4 2 m 4 3 m 4 4 m 4 7 m 5 m 3 5 m 3 6 m 3 7 m 4 2 m 4 3 m 4 5 m 4 7 m 4 9 m 5 m MOOVI 30 RMM ATG 3 AQG 3 B MIN L 2 5 m 2 6 m 2 6 m 2 9 m 2 7 m 2 8 m 2 9 m 2 7 m 2 8 m 2 9 m 2 9 m MAX L 3 m 3 m 3 m 3 m 3 m 3 m 3 m 3 m 3 m 3 m 3 m C MIN L 2 9 m 1 7 m 1 7 m 1 8 m 2 1 m 2 1 m 2 2 m 2 3 m 2 4 m 2 5 m 2 7 m 1 9 m 2 m 2 1 m 2 4 m 2 4 m 2 6 m 2 7 m 2 8 m 2 9 m MAX L 3 m 3 m 3 m 3 m 3 m 3 m...

Page 22: ...MOOVI 30S 30RMM 50RMM Ver 06 67 D811480_07 ...

Page 23: ......

Reviews: