BFT DEIMOS BT H QSC Installation And User Manual Download Page 10

INSTALLATION MANUAL

1) FOREWORD

The DEIMOS BT H QSC actuator is highly versatile in terms of installation options 

due to the extremely low position of the pinion, the actuator’s compact nature 

and the height and depth adjustment features it offers.  The adjustable electronic 

torque limiter provides anti-crush safety. Manual emergency operation is extremely 

easy to perform using just a knob. 

Stopping at end of travel is controlled by electromechanical microswitches.

The built-in control panel controls the start relays and safety devices (photocells, 

safety edge) each time before performing any operation.  

2)  TECHNICAL SPECIFICATIONS 

MOTOR

Power supply

single-phase 230V ±10%, 50Hz (*)

Motor

24V 

Power input

70W

Max. current demand

0,5A (230V~) - 1A (110V~)

Pinion module

4mm  (14 teeth)

Leaf speed

12m/min 

Max. leaf weight

5000N (≈500kg)

Max. torque

20Nm

Impact reaction

Electronic torque limiter

Lubrication

Lifetime greased

Manual operation

Knob-operated mechanical release

Type of use

intensive

Buffer  batteries  (optional 

extras)

Two 12V 1.2Ah batteries

Environmental conditions

from -15°C to +40°C

Protection rating 

IP24

Noise level

<70dBA

Operator weight

7kg (≈70N)

Dimensions

See Fig. K

CONTROL UNIT

Accessories power supply

24V ~ (180 mA)

Fuses

Fig. G

Built-in Rolling-Code radio-receiver frequency 433.92MHz 

Setting  of  parameters  and 

options

Universal handheld programmer/LCD display

N° of combinations

4 billion

Max. n° of remotes that can 

be memorized

63

(*) Special supply voltages to order.

Usable transmitter versions:

All ROLLING CODE transmitters compatible with

3) TUBE ARRANGEMENT Fig.A

Install the electrical system referring to the standards in force for electrical systems CEI 

64-8, IEC 364, harmonization document HD 384 and other national standards. 

4)  PREPARATION FOR MOTOR MOUNTING  FIG.B

•  Make a hole in the ground to accommodate the concrete pad, with anchors 

embedded in the base plate for fastening the gearbox assembly, keeping to 

the distances featured in FIG.B.

•  To keep the base plate in the right position during installation, it may be 

useful to weld two iron plates under the track to which the anchors can then 

be welded (FIG.M).

5) MOUNTING THE MOTOR FIG.C

6) MOUNTING DRIVE ACCESSORIES FIG.D-D1

7) RACK CENTRING WITH RESPECT TO PINION FIG.N-O1-P

DANGER - Welding must be performed by a competent person issued 

with the necessary personal protective equipment as prescribed by 

the safety rules in force FIG.O.
8) FASTENING LIMIT SWITCH BRACKETS FIG.E

9) STOPS FIG.Q

DANGER - The gate must be fitted with mechanical stops to halt its 

travel both when opening and closing, thus preventing the gate from 

coming off the top guide. Said stops must be fastened firmly to the ground, 

a few centimetres beyond the electric stop point.

10) MANUAL RELEASE (See USER GUIDE -FIG.2-).

Warning Do not JERK the gate open and closed, instead push it GENTLY to 

the end of its travel.

----------------------------------------------------------

11) TERMINAL BOARD WIRING Fig. F-G

Once suitable electric cables have been run through the raceways and the auto-

mated device’s various components have been fastened at the predetermined 

points, the next step is to connect them as directed and illustrated in the diagrams 

contained in the relevant instruction manuals. Connect the live, neutral and earth 

wire (compulsory). The mains cable must be clamped in the relevant cable gland 

(FIG.R-ref.P1), and the accessories’ wires in the cable gland (FIG.R-ref.P2), while 

the earth wire with the yellow/green-coloured sheath must be connected in the 

relevant terminal (FIG.R-ref.S). 

TERMINAL DESCRIPTION

1-2

Motor connection.

3-4

24V transformer secondary windin (3-, 4+).  

5-6

Closing limit switch SWC (5 Black common - 6 Red).

5-7

Opening limit switch SWO (5 Black common -7 Brown).

8-9

Flashing light 24V max. 25W. 

10-11

Antenna (10 signal - 11 braiding). 

Use an antenna tuned to 433MHz.

Use RG58 coax cable to connect the Antenna and Receiver.

Metal bodies close to the antenna can interfere with radio recep-

tion. If the transmitter’s range is limited, move the antenna to a 

more suitable position.

12-13

Accessories power supply:

24 V operation with mains power on.

24 V (12-,13+) operation with no mains power and optional 

buffer battery kit. 

14-15

Free contact (NO). 

Gate Open Light SCA (24V max. 3W) or 2nd radio channel output 

(FIG.G-ref.1). 

This option can be set via the “logic menu”.

16-17

Safety device power supply output (photocell transmitter and 

safety edge transmitter). 

N.B.: output active only during operating cycle. 

24 V Vsafe operation with mains power on.

24 V  (16 -,17+) Vsafe operation with no mains power and optional 

buffer battery kit. 

18

Safety device test input FAULT - PHOT (N.O.).

19-20

PEDESTRIAN control button (N.O.) 

Opens the gate by the distance set with the “Partial Opening” parameter

21-22

START/CLOSE control button (N.O.). This option can be set via 

the “logic menu”. Start - operation according to 3/4-step logic 

Close - The command causes the leaf to close.

21-23

STOP input (N.C.)

The command stops movement.

If not used, leave jumper inserted.

21-24

PHOTOCELL input (N.C.)

Operation according to photocell during opening logic.

If not used, leave jumper inserted.

21-25

Safety edge input BAR (NC).

The command reverses movement for 2 secs.

If not used, leave jumper inserted.

21-26

OPEN control button (N.O.). 

Gate opened with this command.

27

Safety device test input FAULT - BAR

31-32

230V~ transformer primary winding.

33-34

Single-phase power supply 230V, 50-60Hz (33N - 34L).

12) SAFETY DEVICES

NOTE: ONLY USE RECEIVING SAFETY DEVICES WITH FREE CHANGEOVER 

CONTACT.

12.1) TESTED DEVICES (FIG. U)

12.2) NON-TESTED DEVICES (FIG. H, U)

13) CALLING UP MENUS: FIG. 1

13.1) PARAMETERS MENU (

PARA

)  (PARAMETERS TABLE “A”)

13.2) LOGIC MENU (

LOGIC

) (LOGIC TABLE “B”)

13.3) RADIO MENU (

radio

)  (RADIO TABLE “C”)

-   IMPORTANT NOTE: THE FIRST TRANSMITTER MEMORIZED MUST BE 

IDENTIFIED BY ATTACHING THE KEY LABEL (MASTER).

In the event of manual programming, the first transmitter assigns the RECEIVER’S 

KEY CODE: this code is required to subsequently clone the radio transmitters.

The Clonix built-in on-board receiver also has a number of important advanced 

features: 

•  Cloning of master transmitter (rolling code or fixed code).

•  Cloning to replace transmitters already entered in receiver.

•  Transmitter database management.

•  Receiver community management.

20  -

  DEIMOS BT H QSC

D811788 00100_01

Summary of Contents for DEIMOS BT H QSC

Page 1: ...R ZAHNSTANGEN SCHIEBETORE SERVOMOTOR PARA CANCELAS CORREDERAS DE CREMALLERA ACTUATOR VOOR SCHUIFHEKKEN MET TANDHEUGEL Attenzione Leggere attentamente le Avvertenze all interno Caution Read Warnings in...

Page 2: ...ssori trasmissione Mounting drive accessories Montage accessoires transmission Montage Antriebszubeh r Montaje de accesorios transmisi n Montage accessoires overbrenging Fissaggio staffe finecorsa dx...

Page 3: ...SCA II CH 15 JP9 14 15 24 V VSAFE VSAFE 24V 0V 25W max LOGICA test fotocellule OFF Photocell test LOGIC OFF LOGIQUE essai photocellules D sactiv e LOGIK Test Fotozellen OFF L GICA prueba fotoc lulas O...

Page 4: ...ning 99 99 99 99 99 99 Speed during closing 99 99 99 99 99 99 Partial opening 40 40 40 40 40 40 Zone 0 0 0 0 0 0 Slow down distance 0 0 0 0 0 0 Opening deceleration space 10 10 10 10 10 10 Closing dec...

Page 5: ...K N M O P CFZ CP 37 30 12 28 22 22 CVZ 28 60 6 40 NO OK Q R P1 P2 S L 249 131 118 1 6 0 265 122 50 2 2 4 3 O1 8888 100 25 50 25 2mm 10 DEIMOS BT H QSC D811788 00100_01...

Page 6: ...2 23 24 25 26 27 JP2 JP1 31 32 33 34 COM NC BAR2 COM NC SWC NC SWO 24 V 0 V 0 V V Safe V Safe RX RX TX TX 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 JP2 JP1 31 32 33 34 CO...

Page 7: ...6 13 12 21 25 17 Bar 2 1 2 3 4 5 6 13 12 27 21 17 Bar 1 1 2 3 4 5 6 13 12 21 25 17 Bar 2 1 2 3 4 5 6 13 12 5 SCS1 MA 4 SCS1 MA 2 SCS1 MA 1 SCS1 MA 17 Bar 3 1 2 3 4 5 6 13 12 27 21 17 6 SCS1 MA Bar 1...

Page 8: ...ed svo opening limit switch input activated svc closing limit switch input activated set the board is standing by to perform a com plete opening closing cycle uninterrupted by intermediate stops in or...

Page 9: ...d If the automated system is installed at a height of less than 2 5 m or is accessible the electrical and mechanical parts must be suitably protected Install any fixed controls in a position where the...

Page 10: ...s components have been fastened at the predetermined points thenextstepistoconnectthemasdirectedandillustratedinthediagrams containedintherelevantinstructionmanuals Connectthelive neutralandearth wire...

Page 11: ...sting more than 2 devices Ref 4 5 D E Fig V the SCS MA auxiliary board must be used 15 4 Interface with WIEGAND systems via SCS WIE module Refer to the SCS WIE module s instructions 13 1 TABLE A PARAM...

Page 12: ...mode radio prog ON Remote control programming ON Enables wireless memorizing of transmitters 1 Press in sequence the hidden key P1 and normal key T1 T2 T3 T4 of a transmitter that has already been mem...

Page 13: ...are in prossimit delle cerniere o organi meccanici in movimento Non contrastare il movimento dell anta e non tentare di aprire manualmente la porta se non stato sbloccato l attuatore con l apposita ma...

Page 14: ...eanswerablefordamage caused by failure to comply with the instructions featured herein Whilewewillnotaltertheproduct sessentialfeatures theFirmreservesthe right at any time to make those changes deeme...

Page 15: ...rAktualisierungdesvorliegenden Handbuches nderungen zur technischen konstruktiven oder handelste chnischen Verbesserung vornehmen ADVERTENCIAS PARA EL USUARIO E ATENCI N Instrucciones de seguridad imp...

Page 16: ...leren en de personen op een afstand houden tot deze niet volledig gesloten is Opletten wanneer de deblokkering wordt geactiveerd indien aanwezig omdat een open rolluik snel zou kunnen vallen in aanwez...

Page 17: ...DEIMOS BT H QSC 47 D811788 00100_01...

Page 18: ......

Reviews: