Overview of System 

 

Please read this entire manual before attempting to install this system. 
This system should only be installed by a professional automatic gate installer or access control 
specialist dealer. 
It is recommended that the system be set up, configured, commissioned and tested on a 
workshop bench 

before

 taken to site for installation. 

 

Site Survey 

 

Before installing this system, you need to be sure that there is good mobile GSM cell coverage in 
the area it is to be installed. It is recommended that you conduct a site survey, and check 
reception on the site for a GSM network. If reception is poor in the area, then this system is not 
recommended. 
 

SIM Card 

 

You will need a SIM card in order to use this system. It should be a regular voice and SMS text 
SIM card. Do not use a data only SIM, as this is only for tablets and will not work in the unit.  

 

 
 
 
 

   

 

 
 

Power 

 

 

TIP: Most technical calls received are due to installers using CAT5 or alarm cable to power 
the unit. Neither are rated to carry enough power (2 amp peak). Please use following 
cable

… 

Up to 2 metres (6 feet) 

– Use minimum 0.5mm

2

 (18 gauge) 

Up to 4 metres (12 feet) 

– Use minimum 0.75mm

2

 (16 gauge) 

Up to 8 metres (24 feet) 

– Use minimum 1.0mm

2

 (14 gauge) 

 

Using insufficient power cable thickness will cause excessive stress on electronic components, 
and therefore void the manufacturer’s warranty. 

        

To avoid such problems it is recommended (and is good practice) to locate the power supply as 
close to the device as possible. This avoids power cable noise and interference and enhances the 
lifetime of the product. 

 

1) Ensure the SIM has calling credit, and can make and 
receive calls on a mobile cell phone. 
2) Check that the SIM is not locked to a phone and can be 
used in other devices. 
3) Check that the SIM does not have a PIN code request. 
4) Disable voicemail service on the SIM. 

4) You are now ready to begin programming

Summary of Contents for Prime

Page 1: ...nual For Cell Switch Prime GSM Cellular Gate opener and GSM alarm signalling device BFT Americas 6100 Broken Sound Parkway N W Suite 14 Boca Raton FL 33487 www bft usa com Toll Free 877 995 8155 Office 561 995 8155 Fax 561 995 8160 ...

Page 2: ...Device Pg 6 Internal Clock Function Pg 7 Winter Summer Daylight Saving Pg 7 Set Automatic Triggering Times Pg 7 Delete all Automatic Triggering Times Pg 8 Notification Number Pg 8 Programming as an Alarm Dialling Device Pg 8 Complete List of Parameters Pg 8 Controlling Relays when used as Alarm Pg 10 Control by SMS Pg 10 Check Door Gate Status Pg 10 Setting up the free App Pg 10 Using the Android ...

Page 3: ...lets and will not work in the unit Power TIP Most technical calls received are due to installers using CAT5 or alarm cable to power the unit Neither are rated to carry enough power 2 amp peak Please use following cable Up to 2 metres 6 feet Use minimum 0 5mm2 18 gauge Up to 4 metres 12 feet Use minimum 0 75mm2 16 gauge Up to 8 metres 24 feet Use minimum 1 0mm2 14 gauge Using insufficient power cab...

Page 4: ...he door Do NOT force it Connections on the GSM Controller N C COM N O GSM modem N C COM N O Out 1 Out 2 eg 12 24ac dc Optional input trigger for alarm device function Optional exit button triggers output 1 for programmed time 12 24v ac dc Optional gate position limit switch Relay outputs Signal LED CPU Power Micro SIM Insert this way Output Connections Example Do not use a SIM card for a tablet as...

Page 5: ...utput 1 will be triggered and if the 78 feature is programmed the unit will send an SMS Powering Up Perform a final check of wiring making sure that the power supply is no more than the absolute maximum is no more than 26v AC and ensure the antenna is connected before switching on the power Once the power is switched on the power LED should illuminate TIPS My GSM LED is still searching Check the S...

Page 6: ...to another network which may have better coverage Programming as a Gate Door Access control Device The unit is able to store up to 100 telephone numbers which can call the intercom and trigger the relay automatically with caller ID Programing text messages must start with a pass code string followed by a command followed by data and each command is separated in the SMS by Send the SMS 20 as shown ...

Page 7: ... a schedule It will send an SMS to itself to check time every set number of days according to the function below 9999 87 Pass code Function code 1 99 days 0 no SMS sheduling Set Automatic Triggering times This feature is useful to automatically trigger electric gates at pre set times of the day or night For gates not set on auto closing this can be used to have opened and closing times with moment...

Page 8: ...ster user phone number every time the intercom is used to grant access It will send a SMS any time a relay is activated To use this feature firstly turn the function on 9999 802 change 2 to 1 to disable again Now you must store the phone number which is to receive the notification 9999 78number Now you may store a customised SMS content which will be sent to the stored number 9999 79enter any text...

Page 9: ...his to avoid voicemail picking up a call 10 99 secs 20 secs 46 Calling time for second number adjust this to avoid voicemail picking up a call 10 99 secs 20 secs 47 Calling time for third number adjust this to avoid voicemail picking up a call 10 99 secs 20 secs Scheduled service calls 77number Store a service number to receive a scheduled call or SMS from the unit Useful for SIM cards which are n...

Page 10: ...ontrol the relays with DTMF touch tones on their phone as follows Control by SMS This device allows the user to send SMS commands to control the relays as follows 1234 1 Relay 1 momentary trigger 1234 2 Relay 1 latch ON or hold ON 1234 3 Relay 1 unlatch or switch OFF 1234 4 Relay 2 momentary trigger 1234 5 Relay 2 latch ON or hold ON 1234 6 Relay 2 unlatch or switch OFF Check if door or gate is op...

Page 11: ... App on Android Iphone Android and Iphone users can download an optional app called BFT Cellbox PRIME This makes the procedure of triggering gates and creating automatic trigger times easy for the end user Android Setup Apple Setup ...

Page 12: ...ult engineers code or user code have been changed from their defaults then please change as required in the relevant section above IMPORTANT On using the app if you receive an error message stating Command Failed go to Settings Application Manager Permissions and turn on all permissions for the app Now you should be ready to use the app Using the App on Android ...

Page 13: ...intercom for output 2 UNLATCH UNHOLD Press to release a latched relay allow gates to close LATCH HOLD OPEN Press to hold ON the relay Press to change controls from relay 1 to relay 2 useful for pedestrian gates HOME TIME SETTINGS Features such as auto triggering do not disturb activity log NOTIFICATION OPTION Press to setup SMS notifications when gates are triggered ...

Page 14: ...y trigger gates to perhaps open every morning at a pre set time or close every night at a pre set time TIP Enter times in 24 hour format without any colon E g 10pm should be entered as 2200 select the days and press SAVE Can be used to send a SMS notification to a master user each time someone calls the device and access is granted Toggle the feature on firstly Then enter a phone number which will...

Page 15: ...ller ID access numbers Check signal strength on your intercom Level 1 31 Must be above 14 for successful operation Check last 20 users who triggered gates including date and time date is international format DD MM YYYY Check the state of both relays ON or OFF ON latched open state Check status of gate limit switch if fitted ...

Page 16: ...to hold ON the relay TIME SETTINGS Features such as auto triggering do not disturb activity log set clock etc Press to change controls from relay 1 to relay 2 useful for pedestrian gates UNLATCH UNHOLD Press to release a latched relay allow gates to close NOTIFICATION OPTION Press to setup SMS notifications when gates are triggered KEYPAD SETTINGS Not used on this device ...

Page 17: ...y trigger gates to perhaps open every morning at a pre set time or close every night at a pre set time TIP Enter times in 24 hour format without any colon E g 10pm should be entered as 2200 select the days and press SAVE Can be used to send a SMS notification to a master user each time someone calls the device and access is granted Toggle the feature on firstly Then enter a phone number which will...

Page 18: ...nd I for dial in caller ID access numbers Check signal strength on your intercom Level 1 31 Must be above 14 for successful operation Check last 20 users who triggered gates including date and time date is international format DD MM YYYY Check the state of both relays ON or OFF ON latched open state Check status of gate limit switch if fitted ...

Page 19: ... the number is entered as you would normally dial it from another phone Q The keys do not work when the device calls a phone A Check if you can hear the relay clicking at the gate when the keys are pressed during a call If it can be heard then the system is working check wiring between the relay and the lock or gate panel If the relays do not make a clicking sound then check this feature on a diff...

Page 20: ...v adaptor in kits 2 2 Software feature added for call log to show last 25 caller ID calls 3 2 Main capacitor regulator diode upgraded for 24v dc 4 2 24v ac power board added to allow 24v ac power input 4 6 PRIME model new firmware larger flash storage Micro SIM holder antenna connects direct to PCBA Red colour PCBA all black model design ...

Page 21: ...P a g e 21 ...

Reviews: