Fig. 6
g)
Fit the wallplugs provided and screw the fixing eyes securely into the
rear of the fire opening.
h)
Whilst the fire box is still in position, decide which side the gas supply is
to enter the fire from. Plan the pipe run to enter the fire box through
one of the openings in the sides of the fire box below the fuelbed
support panel and connect to the isolating / inlet elbow. The gas
connection to the appliance should be made to the isolating / inlet elbow
using 8mm rigid tubing.
There must be no soldered joints within the
firebox.
See fig. 7 below.
Fig. 7
Firebox
Casting
Builders
Opening
Gas Supply
Firebox
Approx.
40mm
Casting
Gas Supply
Approx.
40mm
Builders
Opening
20mm
500mm
Fireplace Opening
100mm
250mm