Unite AP4 – Access Point
18
8. Technical specifications
External power supply
Input voltage . . . . . . . . . . . . . . . . . . . . . . 100 – 240 V AC, 47-63 Hz
Input current . . . . . . . . . . . . . . . . . . . . . . max. 0,8 A
Output voltage . . . . . . . . . . . . . . . . . . . . 12 V DC
Output current. . . . . . . . . . . . . . . . . . . . . 3 A
Power cable . . . . . . . . . . . . . . . . . . . . . . . included, depending on the region
Cable length . . . . . . . . . . . . . . . . . . . . . . 2 m [2.19 yds.]
Unite AP4
DECT RF frequency range . . . . . . . . . . . . . 1880 - 1930 MHz, depending on the country
DECT transmission power . . . . . . . . . . . . . . up to 250 mW (peak), depending on the country
DECT operating range . . . . . . . . . . . . . . . . . up to 300 m outside (line of sight);
the actual operating range depends upon the
RF output settings, the surroundings, the signal
absorption, signal reflection and signal interference
RF coverage . . . . . . . . . . . . . . . . . . . . . . . . . . . up to 10,000 m
2
; the actual coverage depends upon the
RF output settings, the surroundings, the signal absorption,
signal reflection and signal interference
Audio bandwidth
High quality (HD) . . . . . . . . . . . . . . . . . . . . . 50 Hz - 14 kHz (-3 dB)
Operating mode . . . . . . . . . . . . . . . . . . . . . . . Broadcast (4 channels)
Encryption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AES-256 bit encryption
Antenna . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Diversity, internal
Polar pattern of antennas . . . . . . . . . . . . . two omnidirectional antennas with front-facing main lobe
Minimum distance between
several Unite AP4 devices . . . . . . . . 2 m [2.19 yds.]
Connections . . . . . . . . . . . . . . . . . . . . . . . • Ethernet (RJ 45)
• USB-C (currently not implemented)
• DC input, DC 12 V, power consumption max. 12 W
• Sync input (RJ 45)
• Sync output (RJ 45)
• Digital: Dante® (RJ 45; PoE: 12 W IEEE 802.3af-2003,
36 V - 57 V)
• Analogue: Phoenix® socket, balanced,
contact spacing 3.5 mm [0.14"], two-rowed, 6-pin,
balanced and shielded connecting cables required
Input level (4-channel In): max. +7 dBu
Input level for 0 dBFS @ 0 dB Gain: +5 dBu
Attention:
• If several Unite AP4 are used in one room, a minimum distance of 2 m must be
maintained between the individual units to avoid radio disturbances. The cable length
between two devices must not exceed 100 m. The total length of all Sync cables used to
connect the Unite AP4 devices to each other
must not exceed 700 m
.