41
3.2
Setting up
1. Open the battery compartment (10) as indicated by the arrows and insert a 9 V alkaline
battery observing the po/- marks.
2. Instead of alkaline batteries you can also use V 7/8 H type rechargeable batteries. The
SLG 44/500 charging unit can be used for charging this type of battery whilst still fitted in
the transmitter.
3. Plug a suitable microphone or instrument into the lemo socket (1). The attenuation switch
allows you to reduce the input sensitivity 26 dB for instruments and microphones when a
close miking technique is used.
4. Switch on the beltpack transmitter (5).
5. If you want to change the frequency, turn the frequency select control (6) with a suitable
screwdriver or trim tool until it points to the desired frequency. For available frequencies
refer to the frequency table (11). Make sure that the transmitter and receiver are selected
to the same frequency.
6. The operating control LED (4) is illuminated green, if the battery has been inserted
correctly and has full capacity.
7. As the battery voltage decreases below 6.5 V, the operating control LED capacity (4) will
flash. To avoid distortion replace or recharge the battery immediately. A 9 V alkaline
battery should be replaced within 15 minutes of the low battery indicator flashing. If the
battery voltage drops below 6.0 V the operating control LED (4) goes out and the
transmitter is switched off.
CAUTION!
•
The TS 500 beltpack transmitter is equipped with
two external charging contacts
providing an
operating voltage of 9 V
.
•
The TS 500 beltpack transmitter should be applied so that it has
no contact to the skin
,
because due to sweat a
current flow can occur
and
cause skin damages
.
•
If contact to the skin cannot be avoided then
apply protection
to the charging contacts
(for example tape).
•
If you are
allergic to metals
the TS 500
must not have
contact to the skin.
3.3
Recharging of Batteries
Put the transmitter
TS 500 with the rechargeable battery installed into the SLG 44/500
recharging unit. Switch the transmitter off before and during the charging process! During the
charging process a green LED flashes on the charging unit. As soon as the battery is recharged,
the flashing changes into a permanent illumination. For detailed instructions refer to
“Operating Instructions SLG 44/500”.