K12 Installation & User Manual 

1

Choose password 

The first thing to do before you can start pro-
gramming is to choose a password. 

Press and hold the SW1 button on the code 
lock’s circuit board. Both LEDs are lit. 
Enter a 6-digit password. 
Make a note of the new password in the 
chart at the back of the manual.

Change password

Press B and enter the current password.
Enter 

A27

.

Enter the new password. A warning tone is 
heard.
Enter the new password once again.
Press B to leave programming mode.
Make a note of the new password in the 
chart at the back of the manual.

1�

2�
3�

1�
2�
3�

4�
5�
6�

Summary of Contents for K12

Page 1: ...1 2 3 6 5 9 8 4 7 B 0 A 1 8 5 3 2 6 K12 Installation User Manual EN ...

Page 2: ...AB which develops and markets a complete security product range that includes access control and alarm Sales installation and servicing are handled by a national dealer network Actions such as unauthorised manipulation copying etc must not be taken with the software contained in the products and systems Such actions are regarded as copyright violation and may result in imprison ment or fines and m...

Page 3: ...12 Buzzer and LEDs 12 Choose password 13 Change password 13 Select Alarm by pass relay mode 14 Program codes 15 Erase codes 16 Change codes 17 Set opening time 18 Set door held warning time 19 Door control on off 20 Alert output on off 21 Duress output on off 22 Background lighting on off 23 Erase the memory 24 Using K12 25 Entrance 25 Activating an intruder alarm 25 Deactivating an intruder alarm...

Page 4: ... one code The advantage of using two relay outputs is that two functions can be activated at the same time using only one code For example the code can deactivate an intruder alarm and open the lock at the same time For every code you can decide Control an alarm by pass relay and a door relay Control only a door relay Control only an alarm by pass relay Different codes for alarm and door If unique...

Page 5: ... the door is closed during this time both relays are deactivated Note that this requires that door monitor contact be connected See also section Door Control Bistable Using bistable function allows activating an in truder alarm with Code B Any codes for only door opening as well as remote opening will be disabled Note that the alarm relay will change immediately Deactivation of the alarm is done w...

Page 6: ... K12 allows that a bistable alarm can be acti vated using a button or an external timer con nected to an input in the K12 Red LED Control To indicate that the alarm is on the red LED on the front can be lit This is controlled by an external signal connected to the K12 ...

Page 7: ...ing staff s access to the building can be limited to certain hours while tenants staff can have access to the door 24 hours a day By connecting two time clocks to K12 three different time zones can be used to control the codes one controlled by time clock 1 one con trolled by time clock 2 and one that is valid 24 hours a day i e no time control ...

Page 8: ...vated for one of the following reasons A user enters a duress code see the Duress output on off section or The door held warning time expires or the door is forced open see the Alert output on off section Choose which alternative to use Then connect e g a burglar alarm or similar to the output ...

Page 9: ...indicate Alarm on A Used when deactivating an intruder alarm and for programming of the K12 E g A21 to programme codes Yellow LED Indicates key presses Green LED Lit when lock is open B Press B and enter the 6 digit password to programme the K12 B is also used when activating an intruder alarm ...

Page 10: ...l nos 9 and 7 5 Output for alert or duress Use E7 relay Connect between terminal nos 10 and 1 6 Input for door contact The contact is closed when the door is closed Terminal 19 and 21 7 Exit button The door opens on closing terminal nos 20 and 21 8 Electric locking device Dashed line refers to locks with fail safe function 9 SW1 push button Used when choosing pass word and erasing memory 10 Alarm ...

Page 11: ...12 Installation User Manual 11 24 23 22 21 20 19 18 17 16 15 14 13 1 2 3 4 5 6 7 8 9 10 11 12 SW1 10 LOCK 1 0V EXIT CONTACT ALARM BY PASS 0V ALARM BUTTON 12 24V LED TAMPER 0V 1 9 7 8 1 2 3 4 5 6 2 11 K12 ...

Page 12: ...g to the instructions below Buzzer and LEDs During programming you will be guided by the buzzer and the LEDs In programming mode before a function is chosen Green and yellow LED flashes During programming Yellow LED goes out Green LED is lit Correct instruction Confirmed by a rising signal consisting of two quick beeps Faulty instruction Confirmed by a falling signal consisting of two quick beeps ...

Page 13: ...oard Both LEDs are lit Enter a 6 digit password Make a note of the new password in the chart at the back of the manual Change password Press B and enter the current password Enter A27 Enter the new password A warning tone is heard Enter the new password once again Press B to leave programming mode Make a note of the new password in the chart at the back of the manual 1 2 3 1 2 3 4 5 6 ...

Page 14: ...er the password Press A81 Choose mode 0 Monostable 1 Bistable Press B to leave programming mode Note that if monostable alarm bypass mode is chosen the alarm by pass relay will change automatically when the door relay is activated by a correct code If the Alarm button input is activated when in bistable mode the relay will change immedi ately without any warning time 1 2 3 4 ...

Page 15: ... digit code must not be the same as the digits in a 4 digit code and the other way around Choose whether or not the code should be disabled from a time clock 0 No time control 1 Code disabled from time clock 1 1 Code disabled from time clock 2 Choose which relay output to control 0 Both relay outputs 1 Door relay Always used in monostable alarm by pass mode 2 Alarm by pass relay Program the next c...

Page 16: ...ent code If it is a 4 digit code enter A after the last digit If it is a 4 digit code enter 0000 If it is a 6 digit code enter 000000 Enter 0000 000000 again Enter 0 Enter 0 once again Erase the next code by continuing from step 3 or press B to exit Press B to leave programming mode 1 2 3 4 5 6 7 8 9 ...

Page 17: ...gain Choose whether or not the code should be disabled from a time clock 0 No time control 1 Code disabled from time clock 1 1 Code disabled from time clock 2 Choose which relay output to control 0 Both relay outputs 1 Door relay Always used in monostable alarm by pass mode 2 Alarm by pass relay Change the next code by continuing from step 3 or press B to leave code program ming Press B to leave p...

Page 18: ... the lock should remain open following a correct entrance code When K12 is delivered the open ing time is 7 seconds for both relays Press B and enter the password Enter A28 Enter the desired opening time 01 99 us ing two digits e g 09 for 9 seconds Press B to leave programming mode 1 2 3 4 ...

Page 19: ...alarm output will be activated The buzzer sounds until the door is closed Note that door contacts must be connected and that Door control must be activated for this to work This is how to change the door held warning time if needed Press B and enter the password Enter A29 Enter the desired door held warning time 01 99 with two digits e g 09 for 9 sec onds Press B to leave programming mode 1 2 3 4 ...

Page 20: ... time has expired and the door is still open If the door held warning time expires and the door is still open the alert output is activated if the Alert function is activated This also hap pens if the door is forced open This is how to activate Door control Press B and enter the password Enter A67 Enter 1 Press B to leave programming mode To deactivate Door control press 0 in step 3 instead 1 2 3 ...

Page 21: ...door contacts must be connected and that Door control must be activated for this to work This is how to deactivate the alert function Press B and enter the password Enter A69 Enter 1 By doing this the Duress output function is activated Press B to leave programming mode To reactivate the function enter 0 in step 3 instead By doing this the Duress function is deactivated 1 2 3 4 ...

Page 22: ...n Press B and enter the password Enter A69 Enter 1 By doing this the Alert output func tion is deactivated Press B To deactivate the function enter 0 in step 3 instead By doing this the Alert output func tion is reactivated The Enter duress code section describes how a user should enter the duress code Note If Duress is activated make sure you have not programmed codes with consecutive digits Code...

Page 23: ...mming Press B and enter the password Enter A65 Enter 0 Press B to leave programming mode To reactivate the buzzer press 1 in step 3 in stead Background lighting on off This is how to turn off the keypad s background lighting if needed Press B and enter the password Enter A60 Enter 0 Press B to leave programming mode To reactivate background lighting press 1 in step 3 instead 1 2 3 4 1 2 3 4 ...

Page 24: ...ress SW1 on K12 s circuit board Enter 112186 Enter 112186 once again The memory is now erased and K12 goes back to the fac tory settings Press B Following are the default factory settings Password 112233 Opening time 7 seconds Door held warning time 20 seconds Background lightning ON Buzzer ON Duress OFF Alert ON Alarm by pass mode Monostable 1 2 3 4 5 ...

Page 25: ...e the blockage enter a correct code twice in succession Activating an intruder alarm Enter code four or six digits Press B to activate Codes only for door unlocking will now be disa bled and the red LED lit if external LED control is installed Deactivating an intruder alarm Enter code four or six digits Press A to deactivate Codes for door unlocking will work and the red LED turns off if external ...

Page 26: ... usual entrance code only add 1 to the last digit in the code Example 1 If the entrance code is 1234 enter 1235 instead Example 2 If the code is 1239 enter 1230 in stead When a duress code is entered the door will open at the same time as the duress output is activated It will remain activated until reset by somebody entering programming mode ...

Page 27: ...35 V DC Power consumption 90 mA with back ground lightning on 60 mA without Maximum load over the relay contacts 2 A 28 V DC Dimensions HxWxD 140x80x40 mm Suitable height 1200 1400 mm from ground to bot tom edge If needed complete the installation with flush mounting kit BB3 ...

Page 28: ...it codes Enter code 4 or 6 digits Enter timing group 0 none 1 group 1 2 group 2 Enter relay output 0 Both 1 Door 2 Alarm Next code Proceed from step 2 Exit Press B back to programming mode Change code Press A22 Enter old code 4 digit code Enter code A Enter new code twice Enter timing group 0 none 1 group 1 2 group 2 Enter relay output 0 both 1 Door 2 Alarm See above Erase code Press A22 See above...

Page 29: ...tep 3 Step 4 Step 5 Step 6 Change password Press A27 Enter new code 6 digits Enter new code again Change opening time Press A28 Enter sec onds 01 99 Change door held warning time Press A29 Enter sec onds 01 99 Background lighting on off Press A60 0 off 1 on ...

Page 30: ...B Function Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Buzzer on off Press A65 0 off 1 on Door control on off Press A67 0 off 1 on Alert Duress Press A69 0 alert on duress off 1 duress on alert off Alarm by pass mode Press A81 0 Monostable 1 Bistable Erase memory Press SW1 Enter 112186 Enter 112186 ...

Page 31: ... o 2 o 1 o 2 o 13 None o 1 o 2 o 1 o 2 o 14 None o 1 o 2 o 1 o 2 o 15 None o 1 o 2 o 1 o 2 o 16 None o 1 o 2 o 1 o 2 o 17 None o 1 o 2 o 1 o 2 o 18 None o 1 o 2 o 1 o 2 o 19 None o 1 o 2 o 1 o 2 o 20 None o 1 o 2 o 1 o 2 o 21 None o 1 o 2 o 1 o 2 o 22 None o 1 o 2 o 1 o 2 o 23 None o 1 o 2 o 1 o 2 o 24 None o 1 o 2 o 1 o 2 o 25 None o 1 o 2 o 1 o 2 o 26 None o 1 o 2 o 1 o 2 o 27 None o 1 o 2 o 1 o...