Figure 8
Figure 9
Figure 10
6. MAINTENANCE
**CAUTION:
All maintenance on BEVLES Heating Holding Cabinets should be performed by trained
personnel using only quality BEVLES parts.
6-1 REPLACINGPARTS
After using the Troubleshooting table (section 5-2) to determine the solution, refer to the appropriate section below. The
tools and equipmentneeded for each repIacementprocedureare listed at the beginning of that procedure.
6-1a. Removing the top mounted heating module.
Required: No tools required
1. Unplug unit from power source.
2. Open top front door and remove water pan and baffles.
3. Using two people, lift the top mounted heating module straight up and off of the cabinet (Fig 8)
4. Set module upside down on a heat resistant surface.
.
6-1b. Removing the front panel from the heating module.
Required: Medium (6') phillips screwdriver, Medium (6') flathead screwdriver
1. Remove all five screws from the face of the front panel (at the four corners and center top).
2. Gently lift off the front panel while guiding attached wires and thermometer probe to prevent
damage. (Fig. 9)
3. Leaving wires attached, gently place front panel face down on a clean work space. (Fig. 10)
4. To replace front cover, reinsert thermometer probe into receptacle, guide wires back into place and
reattach panel with the five phillips head screws.
Figure 11
Figure 12
Figure 13
6-1c. Replacing the power indicator lamp module.
Required: Wiring markers (color or number codes), Electrical tape
1. Remove front panel as found in section 6-1b.
2. Mark all the wires connected to the power indicator lamp module with a color code or number to
make proper re-connection easy (Fig. 11)
3. Remove the wire nuts and free the power indicator lamp module wires.
4. From the back side of the front panel, depress the plastic tabs on the base of the indicator lamp
module and push it out the front of the panel. (Fig. 12)
9
Summary of Contents for CA43-CV13
Page 31: ...31 Notes...