a. Connect Wirelessly:  Turn on the WiFi with the slider at top right 

of the screen. Select the appropriate network and enter the 
password if necessary.  

b. Connect via Ethernet:  The ethernet port on the standup is 

located beneath the power button on the back of the machine. 
Simply plug the cable into the port and it should connect 
automatically. In newer countertop models, the ethernet cable 
hangs from the bottom of the head unit and will thread down 
through the 4” hole in the countertop. And extension cable can 
be used if it does not reach the ethernet jack.  

c. Connect via OptConnect 

TM 

 After installing and initializing the 

OptConnect 

TM 

, enter the Serial Number in the box and press 

Done .  

3. Return to the Service Panel main page and check that the internet is 

properly connected. The icon on the left of the network field should be 
green, with a “Connected” tag and the connection type listed.  

Initial Stocking

 

 
Flavors 
For each flavor, perform the following steps to initialize: 

1. Press the  Restock  button to bring up the flavor list.  
2. Type in the two digit ID number found on the flavor box, and select the 

appropriate flavor for the new concentrate.  
 
Note:  Make sure to go by the number on the box, not just the flavor 
name. Differently numbered flavors can have differing concentration 
dispense ratios. 
 

3. Place a bucket or large container under the nozzle and prime the line 

for at least 15 seconds, or until concentrate freely flows. You can press 
and hold the  Prime  button, or double tap it to let it auto pour. Tap it 
again to stop the flow.  

 
CO 

To initialize the CO 

, press  Restock  and select 5lb or 10lb (we recommend 10lb 

tanks).  

 

                                                   

© 2018 Bevi. All rights reserved.                                                   [email protected]

 

 

Summary of Contents for Standup v1.0

Page 1: ...Bevi v1 0 Installation Guide Last Revision January 2019...

Page 2: ...where it can be overseen by trained personnel The appliance must not be cleaned by a water jet For indoor use only 10 32 C 50 90 F Appliance shall not be installed in an area where a water jet could b...

Page 3: ...Ice Bank Installing the Carbonator Attaching Water Lines Installing the CO2 Tank Installing Flavors Checking the Lines Initializing the Service Panel Connecting to the Internet Initial Stocking Creat...

Page 4: ...the Partner Resource site at partners bevi co Bevi Components Bevi ships on a pallet that contains the internal components for the machine as well as the chassis For detailed information on each comp...

Page 5: ...Flow Compensator and Line Filter Out ow Line with Pressure Regulator Pentek OR 3M Filter CO2 Regulator Drip Tray 2018 Bevi All rights reserved support bevi co...

Page 6: ...use or smaller it will cause ow problems and machine damage Additionally the following components are not included with the unit by default but are necessary for install Flavor Concentrate Boxes 4 10...

Page 7: ...hin 50 ft of the unit Electrical 110 120 VAC 60 Hz 9A max current draw GFCI protected 3 prong outlet Space At least 3 ventilation room behind the machine the Bevi is 22 deep Measuring Water Pressure I...

Page 8: ...ut aside 2 Place the drip tray on the bottom of re ll station and slide into place 3 Plug the Bevi power adapter into back of Bevi then into power outlet do not turn on power switch yet 4 Screw the Wi...

Page 9: ...r out ow line and pressure regulator to the outlet of the lter housing 10 Turn the power button on the back of the machine on to ensure power is working The tablet should turn on and the lights above...

Page 10: ...bove 6 Doing so will cause the carbonator to freeze and can damage the unit Installing the Carbonator 1 Lock the wheels of the Bevi so they do not roll and lift the carbonator into the unit with the o...

Page 11: ...e on the CO2 tank so gas begins to ow and ensure that the valve on the regulator is open pointing downwards 5 Ensure that the pressure on the top gauge the one closer to the CO2 tank reads 87 psi 6 ba...

Page 12: ...and off the spout of the bag The old box can now be removed and discarded 5 Open a new box of avor concentrate by pressing in on the perforated area The label should be inspected to con rm avor number...

Page 13: ...It should only take 30 seconds or so for the touchscreen to boot up Initializing the Service Panel The service panel can be accessed from the main tablet touchscreen To enter the panel 1 Press the Ing...

Page 14: ...l Connecting to the Internet To connect to a network 1 Press the Change button on the top of the service panel 2 Select the appropriate connection type from the three options 2018 Bevi All rights rese...

Page 15: ...ge and check that the internet is properly connected The icon on the left of the network eld should be green with a Connected tag and the connection type listed Initial Stocking Flavors For each avor...

Page 16: ...en properly connected to the internet the page should update itself within a few minutes with the current inventory Final Steps Purging the Carbonator To ensure that the CO2 and water mix properly per...

Page 17: ...Incubation IMPORTANT NOTE Incubation is a mandatory part of the installation process Without it the Bevi temperature will be too high to properly operate Do not skip this step 1 Once all components ar...

Page 18: ...Email support bevi co 2018 Bevi All rights reserved support bevi co...

Reviews: