This is a cord-connected unit, and must be connected to its own 

dedicated

 power supply. Check the dataplate on the 

machine to confirm the voltage and per the dataplate use the correct fuses or HACR circuit breakers.

Note: Do not connect to GFI / GFCI outlets. Connection to that type of outlet can result in product loss due to 
unsafe cabinet temperature when GFI device trips from moisture.

Power Cord

This 115 volt model is equipped with a cord and a 5-15P plug.

If the power cord becomes damaged, it must be replaced 
with the identical cord.

Follow All National and Local Codes 

This unit must be grounded. Do not use extension cords 
and do not disable or by-pass ground prong on electrical 
plug.

Initial Start Up

Plug the power cord into the proper power supply.

The cabinet will soon begin to blow warm air out of the 
top area, and cool air will flow from the inside blower.

The cabinet temperature has been set at the factory and 
should not need adjustment, however if it was changed, 
the standard setting is 0º F.

Cautions

Care must be taken whenever moving or servicing the 
unit. The refrigerant is contained in a sealed system, but if 
released it may be flammable.

Door Reversal Instructions

1.  Remove hinge cover

2.  Remove door from the unit to include the hinge 

mounting brackets

3.  Remove white hole covers from the side of the door 

opening you would like the hinges to be located (do 
not throw away)

4.  On the bottom of the door the same hole plugs are 

present and need to be removed

5.  Take the hole plugs and insert them into the screw 

holes where the hinges were originally located on the 
unit

6.  Install the hinge bracket upright on the unit.  The 

thick portion of the hinge bracket should be on the 
bottom as you mount them

7.  The door portion of the hinges need to be removed 

and rotated 180 degree and remounted

8.  Install the hole plugs that were removed from the 

bottom of the door into the holes where the handle 
was first mounted

9.  Install the handle on what is now the top of the door

10.  Slide door back into position and gently lower into the 

white pivot cam

11.  Replace hinge cover

ELECTRICAL

5-15P

Summary of Contents for UCF Series

Page 1: ...D OPERATING INSTRUCTIONS for all UCF Freezer Models 3779 CHAMPION BLVD WINSTON SALEM NC 27105 Phone 888 845 9800 Fax 800 253 5168 Web beverage air com 809 174A Rev 6 26 2020 SEE BACK COVER FOR WARRANT...

Page 2: ...on information is located with this manual Please complete the card and submit it to Beverage Air within TEN days of installation Failure to properly register equipment may limit or void the warranty...

Page 3: ...rs There may be pinch points near the door hinges Maintenance Do NOT Clean a frozen evaporator with a sharp object Clean a dirty condenser with a sharp object Store gasoline kerosene or any other flam...

Page 4: ...red in any way Alterations or part substitutions will void the warranty Limitations The machine is designed for use indoors in a controlled environment It must be kept dry not overheated or subjected...

Page 5: ...32AHC 25 32 x 32 5 8 x 34 5 8 Glass 1 4 UCFD32AHC 32 x 32 x 34 5 8 Solid 2 Drawers 4 UCF36AHC 36 x 32 x 34 5 8 Solid 2 5 2 UCFD36AHC 36 x 32 x 34 5 8 Solid 2 Drawers 5 2 UCF48AHC 48 x 32 x 34 5 8 Soli...

Page 6: ...in below Floor Load the floor on which the freezer is located must be even and level free from vibrations and strong enough to support the combined weights of the unit and maximum product load Ventil...

Page 7: ...t the process while the cabinet is held in the opposite direction 2 None of the threads on the leg or caster stem should be visible once screwed in 3 Tilt the cabinet in one direction approximately 8...

Page 8: ...5 Install shelves onto clips with the product retention bar facing up Be careful not to dislodge clips during installation 6 Place shelves so that the retaining tab on the clip captures the shelf as...

Page 9: ...ory and should not need adjustment however if it was changed the standard setting is 0 F Cautions Care must be taken whenever moving or servicing the unit The refrigerant is contained in a sealed syst...

Page 10: ...immediately release the melting or defrost button for a manual defrost Note Holding the defrost button in too long will shut the controller off The internal fan will be on when the compressor is on an...

Page 11: ...ressor not through the controller EVAPORATOR FAN The Evaporator Fan turns on when the Compressor is running and the doors are closed The Evaporator Fan is wired to the Fan Contact The Evaporator Fan t...

Page 12: ...FF ON Defrost OFF OFF OFF ON OFF ON Electronic Controller Control Panel Display Defrost LED Alarm LED On fixed Defrost active On fixed ALARM Present Off Defrost is off Flashing ALARM Silenced Off No A...

Page 13: ...ads ON Keyboard Functions UP Quick press and release Increases Set Point Long press and release Increases display brightness DOWN Quick press and release Decreases Set Point Long press and release Dec...

Page 14: ...User Manual for UCF Freezers Beverage Air Rev 06 20 Beverage Air 14 Control Panel Connections Changing the Set point...

Page 15: ...alarm relay beep the buzzer High voltage alarm uLi Line voltage is higher than Cop uLi Always Blink ulo If configured cut in alarm relay beep the buzzer Low voltage alarm LEA Compressor cont inuous ru...

Page 16: ...e with clean water 3 Dry with a soft cloth 4 Polish with a soft cloth wiping with the grain 5 Wipe weekly with stainless steel cleaner Weekly Interior Cleaning 1 Remove all food food related items and...

Page 17: ...t follow these instructions 1 Open the drawer to full extension 2 Push the white locking tabs forward on both sides of the drawer 3 Press down the back of the tabs 4 Slide the drawer out of the cabine...

Page 18: ...lean may void the limited warranty 1 Unplug unit from power supply 2 Remove the Phillips head screws at the top of the panel 3 Once the screws have been removed the you can lower the panel Please note...

Page 19: ...ll amount of cleaner Heat tint or discoloration Penny Brite or Copper Brite Past NuSteel DuBois Temp or Tarnite Revere Stainless Steel Cleaner Allen Polish Steel Bright Tenacious Deposits Rusty Discol...

Page 20: ...p control No cooling compressor hums but does not start Low voltage to unit Compressor starting system failure Check voltage correct as needed Check start relay and start capacitor See next step No co...

Page 21: ...n area free from flame or spark It must also be in a well ventilated area with a nearby open window or door A sign noting service of a system containing propane must be attached to the unit during ref...

Page 22: ...MODELS WHITE BLACK COMPRESSOR DETAIL L E D LAMP START RELAY 10 COMP CONDENSER FAN C R S 2 4 OL 1 R C S C START RELAY 5 COMP CONDENSER FAN C R S 2 OL 1 R C S C 1 2 3 4 S2 DANFOSS CONTROLLER DETAIL COMP...

Page 23: ...E AIR Also this extended compressor part only warranty does NOT apply to any electrical controls condenser evaporator fan motors overload switch starting relay capacitors temperature control filter dr...

Page 24: ...D WE NEITHER ASSUME NOR AUTHORIZE ANY OTHER PERSON TO ASSUME FOR US ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THE SALE OF SAID REFRIGERATION UNITS OR ANY PARTS THERE OF This warranty shall not be...

Page 25: ...___________ Date Of Installation _________________ Cabinet Serial Number _____________________________________________ Location Of Product Business Name _______________________________________________...

Reviews: