![Beverage-Air UCF Series Installation And Operating Instructions Manual Download Page 18](http://html1.mh-extra.com/html/beverage-air/ucf-series/ucf-series_installation-and-operating-instructions-manual_2745092018.webp)
User Manual for UCF Freezers
Beverage-Air
Rev. 06/20
Beverage-Air
18
CONDENSER CLEANING
Rotating fan blade can cause
personal injury.
Unplug unit from power supply
before beginning to clean
condenser
CAUTION
Keeping the condenser coil clean is critical to efficient
operation.
The condenser coil is located right behind the back grille
of the cabinet. It should be inspected once a month and
cleaned as required. Vacuum clean all surfaces of the
condenser. Make sure no fins are bent or damaged in the
process. If there are bent fins, carefully straighten them
so that air can flow through the coils. Failure to keep
the condenser coil clean will lead to poor performance,
excessive power consumption and compressor failure
and may result in loss of property. Failure to keep the
condenser coil clean may void the limited warranty.
1. Unplug unit from power supply.
2. Remove the Phillips head screws at the top of the
panel.
3. Once the screws have been removed the you can lower
the panel.
Please note the electrical cord will still be connected to
the panel.
4. Examine condenser surface, if dusty, brush and
vacuum the dust and lint from the surface of the
coil. Brush up and down to avoid damaging the fins.
Use care to not disturb the wires connected to the
controller.
Note: If the coil is greasy, the coil will need to be
cleaned with coil cleaner and that should be left to an
experienced technician.
5. After the condenser is clean, return the grille panel to
the unit.
6. To reinstall the rear panel line up the bottom of the
panel to the bottom of the unit keeping the screw
holes lined up on the panel and on the unit.
7. Reinstall the Phillips head screw.
8.
Note: Air filters are not recommended as they restrict
the flow of cooling air.
Remove This Panel
Remove These
Screws
Condenser Surface