10. What if there are problems?
Problem
Cause
Solution
No mist is being
emitted from the
device.
Mains adapter is not
plugged in.
Insert the mains adapter into a
suitable socket.
There is not enough wa-
ter in the water tank.
Fill the water tank up to the
“MAX” marking.
Only a small
amount of mist
is being emitted
from the device.
There is too much water
in the water tank.
Pour away excess water from
the water tank until it only
reaches the “MAX” marking.
Ultrasonic vaporiser is
blocked.
Clean the ultrasonic vaporiser
as described in the “Cleaning
and maintenance” chapter.
The LED of the
Mist/timer button
is illuminated and
the device is run-
ning, but no mist
is emitted.
The outlet in the porce-
lain cover is blocked.
Check that the outlet in the
porcelain cover is not blocked.
Condensation is blocking
the ventilation opening in
the water tank.
Open the ventilation cover and
remove the condensation at
the ventilation opening.
If you cannot find a solution to your problem here, contact our Customer Services.
11. Technical data
Product name
LA 40
Supply
Input: 100 – 240 V, ~50/60 Hz, 0.4 A max
Output: 24.0 V
0.5 A, 12.0 W
Water tank capacity
180 ml
Room size
Up to approx. 20 m
2
How it works
Ultrasonic atomiser
Mist settings
Continuous mist and intermittent mist
Running time
approx. 9 hours of continuous mist
approx. 18 hours of intermittent mist
Timer duration
1 hour, 3 hours, 7 hours, continuous operation
Weight
LA 40: approx. 508 g,
Adapter: approx. 80 g
Dimensions
Ø 129 mm x 167 mm
Average active efficiency
≥ 83.13 %