• Before use, make sure the unit and accessories do not have any visible damage. If in doubt, do not use the 

unit and contact your dealer or the customer service address provided. This applies especially to scratches 

and cracks in the glass or cracks in the housing.

• Contact Customer Service or your dealer if the cord or housing are damaged, otherwise you risk an electric 

shock.

• Disconnection from the mains supply is only guaranteed if the mains plug has been removed from the socket.

• If the mains connection cable of this device is damaged, it must be disposed of. If it cannot be removed, the 

device must be disposed of.

Safety advice for your health

 Warning

• 

Risk of burns!

 The filter disc and unit housing become very hot during operation. You could be burnt by 

touching it!

• Do not touch the hot glass when operating the buttons (On/Off and timer). There is a risk of burning.

• Always allow the unit to cool down before you touch it.

• Always remove the mains plug and let the unit cool down before you pack it away.

• Do not touch the unit with wet hands if it is plugged in.

• Do not allow water to spray on the unit.

• The unit must be operated only when it is completely dry.

5. Intended use

The unit is intended for directing infrared radiation at the human body. Any other use is regarded as improper. 

This unit is not designed for commercial use, but for use in the private home!

Safe handling

• This unit is not intended for use by persons (including children) of limited physical or mental abilities or  

insufficient experience or knowledge, unless their safety is supervised by a responsible person or they have 

been instructed in use of the unit by that person.

• Keep children away from packaging materials (risk of suffocation).

• Do not use on babies and small children.

• This device is not intended for use on changing units, cots or similar.

•  Never use the unit near water.

•  The unit should not be used if it has been dropped, exposed to extreme humidity or damaged in any other way.

• Do not immerse the unit in water or other liquids and do not allow liquids to enter the unit.

• Do not leave the unit unsupervised during operation.

• Switch the unit off immediately if it becomes faulty or malfunctions.

When should the unit not be used?

 Warning

It is strongly recommended not to use the unit in the following cases in order to prevent health injuries:

• for person insensitive to heat.
Heat sensitivity can be reduced or increased in the following cases:

• in diabetic patients,

• in people suffering from drowsiness, dementia or a lack of concentration,

• in people with skin changes caused by illness,

• in people with scarred skin in the treatment area,

• in people with allergies,

• in children and elderly people,

• after taking medicine or consuming alcohol.
In cases of acute inflammatory processes, the unit should only be used after consultation with a doctor.

Summary of Contents for IL 50

Page 1: ...IL 50 EN Infrared heat lamp Instruction for use...

Page 2: ...ulates blood flow You should first ask your GP whether its use is medically advisable in particular cases The unit has a high quality glass ceramic plate ceramic infrared Glass ceramic plates are also...

Page 3: ...e Russian Federation and members of the CIS IP21 Protected against solid foreign objects 12 5 mm in diameter and larger and against vertically falling drops of water SN Serial number 4 Warnings and sa...

Page 4: ...igned for commercial use but for use in the private home Safe handling This unit is not intended for use by persons including children of limited physical or mental abilities or insufficient experienc...

Page 5: ...diately in these cases Special care and caution is necessary if using the unit for a long period Do not use the unit if there is the risk of your falling asleep Excessive exposure can result in skin b...

Page 6: ...ket Switch on the unit at the On Off switch 3 The remaining time display 4 shows 15 minutes Warning Do not bump the unit while it is operating or cooling down or you could damage the lamp Set the desi...

Page 7: ...and disconnect the power plug During treatment Examine the part of the body treated frequently and check for skin reactions Cease exposure immediately if there are any signs of oversensitivity or an a...

Page 8: ...on the flat surface 4 Take the cool lamp by the left or right end and press it carefully to the right or left 5 Now lift it forwards and out of the socket Note Use a cloth to hold the new lamp when in...

Page 9: ...be requested from the stated Customer Service address or found at the end of the instructions for use This device meets the requirements of the European Medical Devices Directive 93 42 EEC with amendm...

Page 10: ...lowing are explicitly excluded from this warranty deterioration due to normal use or consumption of the product accessories supplied with this product which are worn out or used up through proper use...

Page 11: ...11...

Page 12: ...12 619 00_IL50_2019 12 05_04_IM2_BEU_EN Beurer GmbH S flinger Str 218 89077 Ulm Germany www beurer com www beurer gesundheitsratgeber com www beurer healthguide com Subject to errors and changes...

Reviews: