BT-532C User manual
44
User input data in AI don't need to use "(" ")" instructions, coding system
automatically inserts,or will got something wrong. such as: GS 74 k 18
"019501234567890 *", 01 is the AI, the following is wrong: GS 74 18 k "(01)
9501234567890 *".
When using connection structure, the middle need to insert FNC1 (C1H Decimal =
193). input example is as follows:
GS 74 18 k "019501234567890 * 193" 029501234567890 * ""
When setting (HRI) print, control characters will replace with a space, and remove
FNC1 ~ FNC4.
Usage example
1b 40 1d 48 02
1d 6b 41 0c 31 32 33 34 35 36 37 38 39 30 31 32
1d 6b 42 0c 30 32 33 34 35 36 30 30 30 30 38 39
1d 6b 43 0c 30 32 33 34 35 36 30 30 30 30 38 39
1d 6b 44 08 30 32 33 34 35 36 30 30
1d 6b 45 08 30 32 33 34 35 36 30 30
1d 6b 46 08 30 32 33 34 35 36 30 30
1d 6b 47 08 41 32 33 34 35 36 30 41
1d 6b 48 08 41 30 32 33 34 35 36 41
1d 6b 49 08 41 30 32 33 34 35 36 41
⑥
Two-dimension Bar Code Command
Setting mode type of QR code
Name
Setting mode type of QR code
Format
ASCII
:
GS (
k
pL pH cn fn n
Decimal
:
29
40
107 pL pH cn fn n
Hexadecimal
:
1D 28
6b pL pH cn fn n
Description
Setting mode type of QR code
Parameter range
pL=3, pH=0
cn=49
fn=67
0 ≤ n ≤ 16
Default
n=3