5.
DELAY CONTROL
– Set the delay time so that the machine waits before automatically dispensing
the next length of tape. The delay can be set from approximately 1 to 30 seconds. Delay is for use
in Auto or 1-2-2 mode only.
6.
MANUAL MODE –
Tape is dispensed immediately each time a dispense key is pressed.
7.
AUTO MODE
– The automatic mode dispensing sequence is started by depressing a dispense key.
The tape length is set by the length dial above the key pressed. The machine waits the set delay
time after the operator removes tape and then automatically dispenses the next piece of tape. The
same length is repeated until either the other dispense key is pressed or the mode is changed.
8.
1-2-2 MODE
– The 1-2-2 mode dispensing sequence is started by moving the mode selector switch
from MAN to the 1-2-2 position and then depressing the left dispense key. The 1-2-2 dispensing
sequence begins by dispensing a length set by the left length dial and then 2 lengths of tape set with
the right length dial. The dispenser waits the set delay time after the operator removes the tape and
then automatically dispenses the next piece of tape. The 1-2-2 sequence repeats until the mode is
changed.
Note: If the machine does not dispense tape when in “Auto’ or “1-2-2” modes, check to make
certain there is no tape stuck in the machine under the tape sensor. The tape sensor is
located under the rear of the heater cover and sees the tape through a hole in the heater
plate. Remove the tape piece to fix the problem. Check for a tape obstruction by lifting up the
heater to view the tape sensor. There should not be any tape visible in the hole area.
Bottom view of Heater