NATURAL GAS CONVERSION
7. Remove the 4 main burner control knobs by grasping and pulling out.
Insert the slotted screwdriver (Not Included) into the hole of each main burner control valve
shaft as shown. Rotate the shaft counterclockwise (to the left) as far as it will go (about 2
complete turns) until it stops. The shaft will now be set in the NG position.
Re-attach the control knobs. Paste the new rating label for NG under the original LP rating
label on the cart door inner panel.
NG Conversion is now completed.
!
CAUTION:
If low flames or burner problems are observed after converting from LPG to NG, the natural gas
lines may not be large enough. Refer to the “From House to Grill” chart on page 36 for natural
gas supply line specifications. Please contact a plumber to assure proper pressure at 7 in.