Control Panel Function
Safety, Alarms and Error Messages
Steam Function
The control panel is installed with 4 malfunction messages
Press the steam button to activate the steam, the symbol will
E0
appear on the display
Issue
Steam generator does not shut down when set
temperature is reached
Steam Adjustment
Issue
Steam generator shuts down before set temperature
Press the steam time/temp adjustment button to change
is reached
the time period or steam temp
Solution - Failed sensor - Replace electric box and cables
E1 /E2
The pre-set time is 60 minutes
Issue
No steam created, as no water in the steam tank
The pre-set temp is 45c
E1 appears if no water enters tank for 2 minutes
Press this button then press + or - to adjust
Tank automatically tries to re-fill, if successful E1 disappears
The time settings available are 0 -120 minutes
Issue
E2 appears if attempt fails and the steam generator stops
The temp settings available are 25 - 60c
Checks
Check water supply is reaching the steam tank
Check cable connections
When the set steam time has been reached the steam will
Check if inlet valve filter on the steam tank is blocked
turn off.
Solution
Re-instate water supply to cabin.
Is water supply turned on, is there a blockage.
When the set steam temperature has been reached the steam
Re-connect cables if dis-connected or replace section
will turn off
required, if unable to re-connect or a cable is damaged
Clear debris in inlet valve
An automated Ozone cleansing function will activate once the
Replace steam generator if inlet valve failed
steam function has been turned off and run for approximately
E3
3 minutes.
Issue
E3 Message as soon as steam function is turned on.
Solution - Turn OFF steam function and turn back on
If message is still present carry out E1 and E2 checks
Issue
E3 Message during steam function use and no steam
Solution - Blown fuse in plug / Replace fuse
Loose connection / Check all wires and connectors
Turn off steam function, then:
Press re-set button on side of steam tank, then turn steam
function back on, if still present replace steam tank.