The connection cable of the OSE unit has the follow wires
:
Brown: Power, plus (24V from controller)
White: Power, minus (0V from controller)
Yellow: Signal (in loop with the AERF receiver, connector 8) (electrical drawing page 15)
Green: Signal (input of the controller, connector 6)
The photo below shows the “possible” connection of 2 OSE units, the signal wires of both units
will connected in line ( serial) (Green, unit 1, from controller; yellow, unit 1, to green of unit 2;
yellow from unit 2 back to controller)
If something happen, the red LED will be “on”.
The reason for that could be the rubber profile of the safety edge is bent or something is pushing
on it.
If nothing touches the safety edge and the LED is “on”, one item is fault.
Either the OSE unit or the light beam of the safety edge.