background image

 

 

Created 11.08.2014: 

Approved 11.08.2014: 

 Bodo Kiesewalter 

 

 

Guide line to check and repair the safety equipment of the 

Robusta Plus Sliding Gate ver. 1.0 

 

 

 

 

 

Contents 

1. Technical data of the Robusta Plus Sliding gate ............................................................................. 1 

2. Checklist in case of failure Drive unit C720 / 721 ........................................................................... 2 

3. Checklist in case of failure Drive unit C746 / 844 ........................................................................... 3 

4. Manual for to check the safety devices of the sliding gates guiding post / lock post .................... 4 

5. AERF System (Wireless Band) ......................................................................................................... 9 

6. Installation of resistive safety strip at the front of the wing of Robusta Plus sliding gate ........... 11 

6.1 Table of required resistive safety strip (SAP code) according the height of the gate ................ 11 

6.2 Procedure to connect resistance safety strip to the AERF system ............................................. 12 

Electrical drawing safety strips E780 ................................................................................................ 14 

Electrical drawing photocells E780 ................................................................................................... 15 

 

 

 

 

 

1. Technical data of the Robusta Plus Sliding gate 

 

 

Type of FAAC unit:______________   Dimension:______________  Construction year:_______ 

 

 

Summary of Contents for Robusta Plus

Page 1: ...evices of the sliding gates guiding post lock post 4 5 AERF System Wireless Band 9 6 Installation of resistive safety strip at the front of the wing of Robusta Plus sliding gate 11 6 1 Table of required resistive safety strip SAP code according the height of the gate 11 6 2 Procedure to connect resistance safety strip to the AERF system 12 Electrical drawing safety strips E780 14 Electrical drawin...

Page 2: ...ht beam sensors of the safety edge if necessary replace the OSE S unit LED FSW CL is off Safety strip close doesn t work Check OSE S unit Connection box guiding post Status LED must be off if status LED is active check light beam sensors of the safety edge if necessary replace the OSE S unit LED Stop is off Check the wire connection of the connection bar J3 Short circuit bridge must be connected f...

Page 3: ...ust be connected from connector 5 to 7 LED FSW OP is off Check the wire connection of the connection bar J1 Short circuit wire must be connected from connector 3 to 11 LED FSW CL is off Photocells doesn t work check wire connection if necessary replace the photocell LED SAVE is off Activate the gate till movement LED SAVE must become active Otherwise Check the wireless band Transmitter receiver of...

Page 4: ...Warning light does not blink Check the bulb if necessary replace it Lamp stays always on replace the board of the warning light IMPORTANT FC1 and FC2 are end indicators when the gate is half way open both LED s will be ON when gate is open or close only one of both will be ON 4 Manual for to check the safety devices of the sliding gates guiding post lock post Type of safety devices 4 1 Safety edge...

Page 5: ... beam will connected to the OSE unit Photo The color code of the wires is written to the OSE unit The light beam consists of transmitter and receiver Both items are equipped with the same cable and the same colored wires White brown green The OSE unit is equipped with a red LED If power is on and everything is OK the red LED is off It means the safety edge is in work and nothing is detecting touch...

Page 6: ... 6 The photo below shows the possible connection of 2 OSE units the signal wires of both units will connected in line serial Green unit 1 from controller yellow unit 1 to green of unit 2 yellow from unit 2 back to controller If something happen the red LED will be on The reason for that could be the rubber profile of the safety edge is bent or something is pushing on it If nothing touches the safe...

Page 7: ... OSE unit SAP code 1017486 If the LED goes off OK if not Exchange the OSE unit SAP code 1017448 4 2 Photocells The photocells consists of 1 transmitter and one receiver Transmitter on the photos below Electrical drawing page 16 With plastic cap Without plastic cap Red LED in ON status One OSE unit is activated or fault the 2nd one is active too LED activ transmitter is working If the LED is off po...

Page 8: ...p Receiver fault signal light beam from transmitter is missing With plastic cap Without plastic cap The upper LED is ON the signal from transmitter will received system is working This LED shows the power for the receiver is OK If it is off the power is missing fault The upper LED is off Signal from transmitter is missing will not received ...

Page 9: ...he gate is open Small distance between transmitter and receiver If so the batteries are empty and they must exchange Use batteries with a power of 3 6v only SAP code for battery 1017580 If the system doesn t work choose the DIP settings of transmitter and receiver as described in point 5 2 If the system is working change back the DIP setting point 5 1 1 and reprogram the system Attention Before th...

Page 10: ...tic signal stop pressing as the receiver will be logged into the memorizing code process 3 Prog LED will be turned on indicating that you are programming transmitters 4 Press PROG button again for 1 5 sec 5 Prog LED will flash indicating that you are programming power supply time 6 Waiting time You must wait for time you need for having the power supply for the OSE 7 Press PROG button again for 1 ...

Page 11: ... mode on motor controller and set FS on Y SA is not available with this firmware version 6 Installation of resistive safety strip at the front of the wing of Robusta Plus sliding gate If the AERF system doesn t work as described in point 5 1 the light beam safety strip in front of the wing can changed to a resistive safety edge 6 1 Table of required resistive safety strip SAP code according the he...

Page 12: ...ent instruction guideline is given by Betafence on an informative basis only 6 2 Procedure to connect resistance safety strip to the AERF system 6 1 Transmitter The resistive safety strip has to connect to connector 1 and 2 of the transmitter The dip switch of the transmitter has to be changed to the follow position DIP 1 ON DIP 2 OFF DIP 3 OFF The photo shows the wire of the safety strip connecte...

Page 13: ...has to be changed to the follow position DIP 1 ON DIP 2 OFF DIP 3 OFF DIP 4 OFF DIP 5 OFF 6 3 FAAC controller Motor Open the programming menu 2nd level F and button The parameter FS has changed to no If the Software is without the parameter FS nothing is to do With these settings the AERF system stays always active with low battery consumption The photo shows the wire blue and grey connected to th...

Page 14: ...14 Created 11 08 2014 Approved 11 08 2014 Bodo Kiesewalter Electrical drawing safety strips E780 ...

Page 15: ...15 Created 11 08 2014 Approved 11 08 2014 Bodo Kiesewalter Electrical drawing photocells E780 ...

Reviews: