SPECIFICATION

RSP-1500-5

MODEL

DC VOLTAGE

RATED CURRENT

CURRENT RANGE

RATED POWER

OUTPUT

VOLTAGE ADJ. RANGE

LINE REGULATION

LOAD REGULATION

SETUP, RISE TIME

HOLD UP TIME (Typ.)

VOLTAGE RANGE

FREQUENCY RANGE

EFFICIENCY (Typ.)

INPUT

INRUSH CURRENT (Typ.)

LEAKAGE CURRENT

OVER TEMPERATURE

WORKING TEMP.

ALARM SIGNAL OUTPUT

REMOTE ON-OFF CONTROL

AUXILIARY POWER

WORKING HUMIDITY

STORAGE TEMP., HUMIDITY

TEMP. COEFFICIENT

VIBRATION

MTBF

DIMENSION

OTHERS

NOTE

PACKING

OVERLOAD

Note.5

OVER VOLTAGE

AC CURRENT (Typ.)

5V

240A

0 ~ 240A

1200W

150mVp-p

4.5 ~ 5.5V

±

2.0%

±

0.5%

±

2.0%

1500ms, 100ms at full load

10ms at full load

14ms at full load

16ms at full load

90 ~ 264VAC          127 ~ 370VDC

47 ~ 63Hz

80%

17A/115VAC         8A/230VAC

30A/115VAC          60A/230VAC

<2.0mA / 240VAC

105 ~135% rated output power

5.75 ~ 6.75V

Protection type : Constant current limiting unit will shut down o/p voltage after 5sec. Re-power on to recover

13.8 ~ 16.8V

17 ~ 20.5V

27.6 ~ 32.4V

31 ~ 36.5V

57.6 ~ 67.2V

Protection type : Shut down o/p voltage, re-power on to recover

Shut down o/p voltage, recovers automatically after temperature goes down

-20 ~ +70

(Refer to "Derating Curve")

Please see the Function Manual.

Power OK signal. Please see the Function Manual.

[email protected](Only for Remote ON-OFF control)

20 ~ 90% RH non-condensing

-40 ~ +85

, 10 ~ 95% RH

±

0.05%/

(0 ~ 50

)

10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

265.3K hrs min.

Telcordia SR-332 (Bellcore) ; 90.3K hrs min.      MIL-HDBK-217F (25

)

278*127*83.5mm (L*W*H)
3.0Kg; 4pcs/13Kg/1.19CUFT

87%

87%

90%

90%

91%

±

0.5%

±

0.5%

±

0.5%

±

0.5%

±

0.5%

±

0.5%

±

0.5%

±

0.5%

±

0.5%

±

0.5%

±

1.0%

±

1.0%

±

1.0%

±

1.0%

±

1.0%

150mVp-p

10 ~ 13.5V

150mVp-p

13.5 ~ 16.5V

150mVp-p

20 ~ 26.4V

150mVp-p

24 ~ 30V

200mVp-p

43 ~ 56V

12V

125A

0 ~ 125A

1500W

15V

100A

0 ~ 100A

1500W

24V

63A

0 ~ 63A

1512W

27V

56A

0 ~ 56A

1512W

48V

32A

0 ~ 32A

1536W

RSP-1500-12

RSP-1500-15

RSP-1500-24

RSP-1500-27

RSP-1500-48

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25  of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. 

 

The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on 

  a 

mm*

mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.

720

360

 For guidance on how to 

    perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)

5. Derating may be needed under low input voltages. Please check the derating curve for more details.

POWER FACTOR (Typ.)

0.95/230VAC          0.98/115VAC at full load

SAFETY STANDARDS

UL60950-1, TUV EN60950-1 approved

RIPPLE & NOISE (max.)

Note.2

VOLTAGE TOLERANCE

Note.3

WITHSTAND VOLTAGE

ISOLATION RESISTANCE

I/P-O/P:3KVAC     I/P-FG:2KVAC     O/P-FG:0.5KVAC

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25

/ 70% RH

ENVIRONMENT

SAFETY &

FUNCTION

EMC

(Note 4)

PROTECTION

OUTPUT VOLTAGE PROGRAMMABLE(PV)

Adjustment of output voltage is allowable to 70 ~ 100% of nominal output voltage. Please refer to the Function Manual.

CURRENT SHARING

Up to 6000W or (3+1) units. Please refer to the Function Manual.

Parameter

Parameter

ESD

Radiated

EFT / Burst

Surge

Conducted

Magnetic Field

Voltage Dips and Interruptions

Conducted

Radiated

Harmonic Current

Voltage Flicker

EN55024 , EN61204-3, EN61000-6-2

Standard

Standard

EN55022 (CISPR22) / EN55011 (CISPR11)

EN55022 (CISPR22) / EN55011 (CISPR11)

EN61000-3-2

EN61000-3-3

EN61000-4-2

EN61000-4-3

EN61000-4-4

EN61000-4-5

EN61000-4-6

EN61000-4-8

EN61000-4-11

Test Level / Note

Test Level / Note

Level 3, 8KV air ; Level 2, 4KV contact

Level 3

Level 3

Level 3, 2KV/Line-Earth ; Level 2, 1KV/Line-Line

Level 3

Level 4

>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods

Class B

Class A

-----

-----

EMC IMMUNITY

EMC EMISSION

REMOTE SENSE

Compensate voltage drop on the load wiring up to 0.3V. Please refer to the Function Manual.

1

5

0

0

W Single Output with PFC Function

MEAN WELL 

RSP

-

1

5

0

0

 SERIES

Summary of Contents for RSP-1500-12

Page 1: ...gn flexibility by equipping various built in functions such as the output programming active current sharing remote ON OFF control auxiliary power etc 48 RSP 1500 Series name Output wattage Output vol...

Page 2: ...e are measured at 20MHz of bandwidth by using a 12 twisted pair wire terminated with a 0 1uf 47uf parallel capacitor 3 Tolerance includes set up tolerance line regulation and load regulation 4 The pow...

Page 3: ...tics INPUT VOLTAGE V 60Hz 100 90 80 70 60 50 LOAD 90 100 120 140 150 160 180 200 220 240 264 EFFICIENCY LOAD The curve above is measured at 230VAC Efficiency vs Load 48V Model MODEL MODEL INPUT INPUT...

Page 4: ...er the output voltage can be trimmed to 70 100 Typ of the nominal voltage by applying Connect an external resistor between on CN1 or CN2 and S V S V also need to be connected TRIM pin4 S pin3 or pin4...

Page 5: ...rnal 12V auxiliary output 2 2K AUX RC1 12V typ AUXG 150 RCG RC2 SW 620 5V 150 RC2 12V typ RCG AUXG 2 2K RC1 AUX SW 150 RC2 12V typ AUXG SW RCG 2 2K RC1 AUX Connection Method CN3 CN2 PIN2 RC2 PIN1 RCG...

Page 6: ...voltage 10mA max Function P OK The signal is Low when the power supply is above 65 of the rated output voltage or say Power OK Description The signal turns to be High when the power supply is under 65...

Page 7: ...wisted in pairs to minimize noise pick up When remote sensing is used in parallel operation the sensing wire must be connected only to the master unit V V V V V V V V AC L AC L AC L AC L AC N AC N AC...

Page 8: ...ignment HRS DF11 8DP 2DS or equivalent CN1 CN2 CN1 and CN2 are connected internally Mating Housing Terminal HRS DF11 8DS or equivalent HRS DF11 SC or equivalent 7 1 Kgf cm 0 Pin No 1 2 Function RCG RC...

Page 9: ...gnment Pin No 1 3 2 Assignment Diagram M x a imum mounting torque 18Kgf cm AC L AC N 2 1 6 5 Control Pin No Assignment HRS DF11 6DP 2DS or equivalent CN3 Mating Housing Terminal HRS DF11 6DS or equiva...

Reviews: