Bestway FLOWCLEAR 58391 Owner'S Manual Download Page 5

• This product is not intended for commercial use.

RCD WARNING

• Risk of electric shock. The RCD plug must be tested before each use.

• Do not use the pump if this test fails. For assistance, please visit the support 

section on our website, www.bestwaycorp.com.

• Insert the RCD plug into a residual current device (RCD) having a rated 

residual operating current not exceeding 30mA.

• Before inserting plug into a power outlet, make sure the current rate of the 

power outlet is suitable for the pump.

SAVE THESE INSTRUCTIONS

TECHNICAL SAFETY INSTRUCTIONS

• Risk of electric shock, never run the filter pump when people are swimming 

in the pool.

• The appliance must be supplied by an earthed power source.

• Do not bury cord. Locate cord to minimize abuse from lawn mowers, hedge 

trimmers, and other equipment.

• This pump is for use with storable pools only. Do not use with 

permanently-installed pools. A storable pool is constructed so that it is capable 

of being readily disassembled for storage and reassembled to its original 

integrity. A permanently-installed pool is constructed in or on the ground or 

in a building such that it cannot be readily disassembled for storage. 

• Using the pump with an unmatched electrical supply is dangerous and will 

result in catastrophic failure of the pump.

• When working with electricity, turn the electrical power off at the circuit breaker 

and lock breaker door. Failure to do so will result in increased risk of shock, 

injury and possibly death. 

• Do not remove the grounding prong or modify the plug in any way. Do not 

use adaptor plugs. Consult a qualified electrician for any questions related 

to the validity of your plugs grounding. 

• Handle the pump with care. Do not pull or carry the pump by the power cord. 

Never pull a plug from the outlet by yanking the power cord. Keep cord free 

from abrasions. Sharp objects, oil, moving parts, and heat should never be 

exposed to the filter pump.

• Cleaning and user maintenance must be performed by an adult above   

18 years old who is familiar with the risk of electric shock.

• In case of doubt on the pump or any circulation devices, contact a qualified 

installer, or the manufacturer/importer/distributor.

• Mind all the safety requirements and recommendations described in the 

manual.

• Atmospheric conditions may affect the performance and life span of your filter 

pump. Unnecessary wear and tear may occur during periods of cold, heat and 

exposure to sun. Whenever possible, shelter the pump from these conditions. 

• It is important to ensure the factory equipped stopper plugs for the inlet and 

outlet ports replace the screens before removal or maintenance on the pump 

is attempted.

• Do not add chemicals in the filter pump.

• Don’t plug or unplug the appliance if your hand is wet.

• Always unplug the appliance: on rainy days, before cleaning or other 

maintenance, and when leaving it unattended on holidays.

MAINTENANCE

• 

Make sure that the Filter Pump is unplugged before any maintenance.

• For the maintenance instructions, refer to illustration steps     inside the manual. Drawings are for illustration purposes only. 

May not reflect actual product. Not to scale.

• To optimize the Filter Pump performance and for sanitary reasons, we suggest replacing the filter cartridge with a new 

one every two weeks.

INSTALLATION

• For the installation instructions, refer to the illustration steps     inside the manual. Drawings are for illustration purposes 

only. May not reflect actual product. Not to scale.

• Bestway will not be responsible for any damage caused to the Filter Pump due to mishandling or failure to follow these 

instructions.

• It is imperative to check that the hydraulic connectors are not obstructed.

• Do not dry run the Filter Pump. Make sure both the pool's inlet and outlet valves are fully covered by water before 

operating the Filter Pump.

SETUP

CHECK LIST 

To check the parts included in the box, consult the part list inside this manual. Verify that the equipment components 

represent the model that you had intended to purchase. In case of any damaged or missing parts at the time of purchase, 

visit our website bestwaycorp.com/support. 

CHOOSE THE CORRECT LOCATION

Place the Filter Pump on a solid and level ground; it must be positioned on the same level as the base of the pool. If the 

Filter Pump is in an upper or lower position than the base of the pool, the performance and life span of the Filter Pump can 

be compromised. The pool and the Filter Pump have to be positioned in an area with adequate drainage and easy access 

for maintenance operations. Never place the Filter Pump in a area that may accumulate water.

5

WARRANTY TERMS

For information concerning warranty terms, visit our website at: www.bestwaycorp.com.

STORAGE

• Remove all accessories; be sure that Filter Pump, hoses and debris screens are completely clean and dry before the 

storage. If all the parts are not completely dry, mold may result.

• Before storage, remove and dispose of the filter cartridge.

• We strongly recommend disassembling the Filter Pump when the environment temperature is below 10ºC / 50ºF.

• Store the Filter Pump in a dry place with a moderate temperature between 10ºC / 50ºF and 38ºC / 100ºF.

256

270

300

450

2-M6 bolt

2-M6 nut

ATTACHING A BASE

EN60335-2-41 TEST standard requires the filter pump to be vertically 

fixed on the ground or a base made of wood or concrete before use. 

There should be two holes 7mm in diameter on the base, the space 

between which should be 256mm. Put filter pump on the base and attach 

them together by fastening the bolts and nuts. All the base parts should 

weigh at least over 18kg to prevent the pump from accidentally falling.

Summary of Contents for FLOWCLEAR 58391

Page 1: ...in der Europ ischen Union vertreten von Prodotto distribuito e rappresentato nell Unione Europea da Bestway Europe S p a Via Resistenza 5 20098 San Giuliano Milanese Milano Italy Distributed in Latin...

Page 2: ...he instructions in a safe place If instruction is missing search it on the website www bestwaycorp com support WARNING The pump is to be supplied by an isolating transformer or supplied through a resi...

Page 3: ...on system Regularly monitor the filter clogging level A weekly check is recommended for cleaning Minimum daily filtration operating time of 8 hours is recommended to ensure clear pool water It is esse...

Page 4: ...an for any questions related to the validity of your plugs grounding Handle the pump with care Do not pull or carry the pump by the power cord Never pull a plug from the outlet by yanking the power co...

Page 5: ...side this manual Verify that the equipment components represent the model that you had intended to purchase In case of any damaged or missing parts at the time of purchase visit our website bestwaycor...

Page 6: ...mindestens 1 2 m angebracht sein Es darf kein Verl ngerungskabel verwendet werden Sollte das Netzkabel besch digt sein muss es durch den Hersteller einen entsprechenden Kundendienst oder hnlich qualif...

Page 7: ...die vom Hersteller empfohlenen Ersatzteile Alle Filter sowie Filtermedien m ssen regelm ig berpr ft werden um ein zufriedenstellendes Filterergebnis zu gew hrleisten Die Entsorgung von gebrauchten Fi...

Page 8: ...sich bitte an einen qualifizierten Elektriker Behandeln Sie die Pumpe mit Vorsicht Verwenden Sie das Netzkabel niemals alsTragehilfe Ziehen Sie niemals einen Stecker entlang des Kabels aus der Steckd...

Page 9: ...s dem Modell entsprechen das Sie zu kaufen beabsichtigt haben Sollten zum Zeitpunkt des Kaufs Teile besch digt sein oder fehlen besuchen Sie uns unter www bestwaycorp com support W HLEN SIE DEN RICHTI...

Page 10: ...r de instructies op een veilige plaats Indien er instructies ontbreken kunt u deze opzoeken op de website www bestwaycorp com support WAARSCHUWING De pomp moet worden gevoed door een scheidingstransfo...

Page 11: ...ekeurd door de persoon die verantwoordelijk is voor het op de markt brengen van het product Alle filters en filtermedia moeten regelmatig worden ge nspecteerd om er zeker van te zijn dat er zich geen...

Page 12: ...rding van uw stekker Ga voorzichtig om met de pomp Trek of draag de pomp niet aan het netsnoer Trek nooit een stekker uit het stopcontact door aan het netsnoer te trekken Houd het snoer vrij van besch...

Page 13: ...e in het geval van beschadigde of ontbrekende onderdelen op het moment van aankoop bestwaycorp com support KIES DE JUISTE LOCATIE Plaats de filterpomp op een stevige en vlakke ondergrond het moet op h...

Page 14: ...ent ne doit pas tre plus de 4 m de la piscine et une hauteur de 1 2 m au moins Les rallonges lectriques ne peuvent pas tre utilis es Si le cordon d alimentation est endommag il doit tre remplac par le...

Page 15: ...ne responsable de la mise sur le march du produit Tous les filtres et les dispositifs filtrants doivent tre inspect s r guli rement pour s assurer qu il n y a pas d accumulation de d tritus emp chant...

Page 16: ...nrelative lavalidit dela mise laterredevotreprise Manipulezlapompeavecpr caution Netirezpasouneportezpaslapompeparlecordon d alimentation Neretirezjamaisunefichedelapriseentirantsurlecordond alimentat...

Page 17: ...es dans une zone avec un drainage ad quat et un acc s facile pour les op rations d entretien Ne placez jamais la pompe de filtration dans un endroit o l eau peut s accumuler CONDITIONS DE GARANTIE Po...

Page 18: ...18 V1 1 1 1 2 V1 V2 1 2 3 4 5 6 7 8 9 10 11 V1 x1 x1 x1 x1 x1 x2 x2 x0 x0 x0 x0 V2 x1 x1 x1 x1 x1 x2 x2 x2 x2 x1 x1 1 2 3 4 5 6 8 9 7 6 10 11 A B A B B A A A B B 1 min 1 2 3 4 5 B A 1 3...

Page 19: ...19 V2 2 1 2 2 A B x2 A A B B A B A B B A 2 3 1 1 1 2 V1 1 min 1 2 3 4 5 B A B A B A 1 2 3 4...

Page 20: ...20 2 1 2 3 2 4 2 2 V2 1 4 1 min 1 2 3 4 5 B A 1 min 1 2 3 4 5 A B x2 1 3 A B 303021293281...