background image

3

SAFETY  INSTRUCTIONS

WARNING

IMPORTANT SAFETY INSTRUCTIONS 

When installing and using this electrical equipment, basic safety precautions should always be followed, 

including the following:

READ AND FOLLOW ALL INSTRUCTIONS

 WARNING - 

TO REDUCE THE RISK OF INJURY -

 

do not permit children to use this product unless they are 

closely supervised at all times.

 WARNING - 

RISK OF ELECTRIC SHOCK -

 Connect only to a grounding type receptacle. This product is provided 

with a ground-fault circuit-interrupter. If replacement of the plug is needed, use only identical replacement parts.

  WARNING - 

The unit is provided with a ground-fault circuit-interrupter (GFCI). To test the GFCI,push the test button. 

The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the 

GFCI is defective. If the GFCI interrupts power to the pump without the test button being pushed, a ground current is flowing, 

indicating the possibility of an electric shock. Do not use this pump. Disconnect the pump and have the problem corrected by a 

qualified service representative before using.

 CAUTION -

 

To reduce the risk of electric shock the pool must be installed no closer than 6 feet (1.8 m) from any 

electrical outlet. Do not place portable appliances closer than 5 feet (1.5 m) from the pool.

  

DO NOT BURY CORD -

 

Locate cord to minimize abuse from lawn mowers, hedge trimmers, and other equipment.

 WARNING -

 

To reduce the risk of electric shock, replace damaged cord immediately.

 WARNING - 

To reduce the risk of electric shock, do not use extension cord to connect unit to electric supply; provide 

a properly located outlet.

 CAUTION: 

This pump is for use with storable pools only. Do not use with permanently-installed pools. A storable pool 

is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity. A permanent-

ly-installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage.Please 

examine and verify all sand filter components are present before use. Notify Bestway at the customer service address listed on this 

manual for any damaged or missing parts at the time of purchase.

  

•THERMALLY PROTECTED MOTOR. CSA ENCLOSURE 3

  • FOR USE WITH SWIMMING POOLS ONLY.

 • CAUTION: 

TO ENSURE CONTINUED PROTECTION AGAINST SHOCK HAZARD,USE ONLY IDENTICAL 

REPLACEMENT PARTS WHEN SERVICING.

 • WARNING: 

RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A GROUNDING TYPE RECEPTACLE.

 • CAUTION:

 

THIS PUMP IS FOR USE WITH STORABLE POOLS ONLY - DO NOT USE WITH PERMANENT-

LY-INSTALLED POOLS.

 • CAUTION:

 

CONNECT ONLY TO GROUNDING TYPE RECEPTACLE PROTECTED BY A CLASS A GROUND 

FAULT  CIRCUIT INTERRUPTER.

 

• CAUTION: 

FOR CONTINUED PROTECTION AGAINST POSSIBLE ELECTRIC SHOCK THIS UNIT IS TO BE 

MOUNTED TO THE BASE IN ACCORDANCE WITH THE INSTALLATION INSTRUCTIONS.

 • WARNING -

 

RISK OF ELECTROCUTION

  

1) Connect Only To Properly Grounded Outlet. Do Not Remove Ground Pin.

  2) Inspect Cord Before Using – Do Not Use If Cord Is Damaged.

  3) Keep Ground-Fault Circuit-Interrupter Dry And Off The Ground.

  4) Do Not Touch Plug With Wet Hands.

  5) Double Insulated – When Servicing Use Only Identical Replacement Parts.

  6) Read Instruction Manual Before Using.

 DO NOT REMOVE THIS TAG

 SAVE THESE INSTRUCTIONS.

  This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device 

  may not cause harmful interference, and (2) this device must accept any interference received, including interference that 

  may cause undesired operation.

 WARNING: 

Any changes or modifications to this unit not expressly approved by the party responsible for compliance 

could void the user’s authority to operate the equipment.

 NOTE: 

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of 

the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This 

equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, 

may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular 

installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the 

equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  - Reorient or relocate the receiving antenna.

  - Increase the separation between the equipment and receiver.

  - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

  - Consult the dealer or an experienced radio/ TV technician for help.

PARTS REFERENCE OVERVIEW

Before assembling the sand filter, take a few minutes to become familiar with all the sand filter parts.

REF.NO SPARE PART NO.

A

B

1

P61973

1

1

2

P61138

1

1

3

P61974

2

2

4

P61209

1

1

5

P61979

1

1

6

P61980

1

1

7

P61211

1

1

8

P6581

1

1

9

P6580

1

1

10

P61981

1

1

11

P6614

1

1

12

P6029

5

5

13

P61971

1

1

14

P61214

1

1

15

P61983

8

8

16

P61970

6

3

17

P61964

5

2

18

P6005

8

2

19

P6124

11

4

20

P6561

1

1

21

P6562

1

1

22

P6563

1

1

23

P61985US

1

1

24

P61978

1

1

25

P61139

2

2

P6680

2

0

P61318

1

0

27

P6132

2

0

28

P6362

1

0

29

P6783

1

1

26

SPECIFICATIONS

Filter Diameter:

Effective Fiter Area:

Max. Operating Pressure:

Working sand filter pressure:

Max. Water Temperature: 

Sand: 

Sand Size:

Sand Capacity: 

254mm

0.05m2(0.54ft

2

)

0.84Bar(12PSI)

<0.45Bar(6.5PSI)

35°C

Not included 

#20 silica sand,0.45-0.85mm

Approximately 9kg

528

m

m

480mm

254mm

(P6680)

(P61318)

X3

A

B

X1

X1

X2

Summary of Contents for 58496E

Page 1: ...79 58496E SAND FILTER OWNER S MANUAL www bestwaycorp com Visit Bestway YouTube channel QUESTIONS PROBLEMS MISSING PARTS For FAQ Manuals Videos Or Spare Parts Please Visit www bestwaycorp com support TO THE STORE ...

Page 2: ...with storable pools only Do not use with permanently installed pools A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity A permanent ly installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage Please examine and verify all sand filter components are...

Page 3: ...easures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help PARTS REFERENCE OVERVIEW Before assembling the sand filter take a few minutes to become familiar with all the sand filt...

Page 4: ...ool grade filter sand Flowclear Polysphere Assembly You will need a screwdriver 1 Carefully remove all components from the package and check to ensure nothing is damaged If equipment is damaged immediately notify the retailer from where the equipment was purchased 2 The sand filter should be placed on solid level ground preferably a concrete slab Position the sand filter so the Ports and Control V...

Page 5: ...5 2 1 A B B A B A B A B A D B B 2 3 1 D Garden hose not included For Drain Backwash Rinse function 5 3 4 B D P6680 A B B D A B B ...

Page 6: ...ator turns red NOTE If the indicator light is not on the test has failed C Press the TEST button The indicator turns off NOTE If the indicator light is not off the test has failed D Press the RESET button the indicator light turns red and the sand filter is ready for use WARNING RISK OF ELECTRIC SHOCK THE GFCI MUST BE TESTED BEFORE EACH USE WARNING DO NOT USE THE PUMP IF THE ABOVE TEST FAILS Pleas...

Page 7: ...e all provisions for wastewater disposal meet applicable local state or national codes Do not discharge water where it will cause flooding or damage When the Control Valve is set to the Backwash Rinse or Drain position water will discharge from Port D on the Control Valve Do not switch on or operate the sand filter with the Control Valve set to the Closed function or it will seriously damage the s...

Page 8: ... water 4 Disconnect the two Hoses from the pool and the sand filter 5 Completely pour the sand out of the tank and dry all components 6 Store the sand filter in a dry location out of child s reach Stopper plugs were not removed Air was not released The control valve is set to Closed The strainer is blocked Sand filter broken Remove the stopper plugs and insert the debris screens Release the air Se...

Reviews: