background image

19

Sling Type

Material 

Sizes

Mesh

M, L

Polyester

M, L, XXL

Mesh

S, M, L

Polyester

S, M, L, XXL

Universal Disposable

Nonwoven, Disposable

M, L

Universal Disposable with Head Support

Nonwoven, Disposable

S, M, L, XXL

Sani

Polyester

S, M, L, XXL

Polyester

M, L, XL

Mesh

M, L, XXL

Invacare® Replacement with Head Support

Mesh

M, L, XL, XXL

Hoyer® Replacement

Polyester

M, L, XL

Hoyer® Replacement with Head Support

Polyester

M, L, XL

Liko®/Guldmann® Replacement

Polyester with PU Coating

M, L, XL

Liko®/Guldmann® Replacement with Head Support

Polyester with PU Coating

M, L, XL

Liko®/Guldmann® Disposable Replacement

Nonwoven, Disposable

M, L, XL

Liko®/Guldmann® Disposable Replacement with Head Support

Nonwoven, Disposable

M, L, XL

Mesh

Polyester

Pediatric with Head Support

Standard

Invacare® Replacement

Universal with Head Support

Universal

Available slings compatible with Patient Lift

If the patient is pregnant or has skin conditions, consult with a 

doctor before use.

ALWAYS check that the sling weight capacity is 

suitable for the patient

All slings are type BF applied parts

20

For further product information and support, please contact your dealer 

or visit our website at www.bestcarellc.com

Summary of Contents for BESTLIFT PL600

Page 1: ...T I E N T L I F T M o d e l P L 6 0 0 Ensure the product has been assembled according to the instructions in this manual All operators should read and understand the instructions for safe and proper o...

Page 2: ...e mast The YY in the serial number is the manufacture year and the MM is the manufacture month MAX LOAD 600LB S N PL600YYMM1XXX BestLift PL600 2920 Pacific Dr Norcross GA 30071 1 678 679 6690 MASS OF...

Page 3: ...ery pack you will never have to be worried about your lift not being charged and ready for use The PL600 is intended to be used with patients who are completely immobile or totally dependent on the pa...

Page 4: ...out its intended Do Not Iron Item may not be smooted or finished with an iron Class II symbol To identify equipment is designed that a connection to electrical earth ground is not required Tumble Dry...

Page 5: ...wise severely handicapped The patient lift should be used solely for transferring a user patient from one utility beds chairs toilets etc to another The patient lift should not be used for transportin...

Page 6: ...xposed that may cause bodily harm or injury Prolonged exposure or physical contact with any part of the equipment WILL NOT cause skin irritation allergic reaction etc Using accessories detachable part...

Page 7: ...400 0 1 0 2 0 3 0 5 Easy Tools Screwdriver 10 2 lb 4 6 kg 11 lb 5 kg 14 6 lb 0 7 lb 0 6 lb 6 6 kg 0 3 kg 0 3 kg 7 4 lb 3 4 kg 9 Boom Emergency Lowering 1 Base 3 Control Unit 7 Front Caster Leg Opening...

Page 8: ...A 1887 8 74 3 B 1197 4 47 1 C 690 1 27 2 D 626 7 24 7 E 998 0 39 3 F 889 0 35 0 G 574 6 22 6 H 262 0 10 3 I 461 7 18 2 J 246 7 9 7 K 427 9 16 8 L 119 4 4 7 M 26 2 1 0 PL600 A B 600 C D G E 700 F H K...

Page 9: ...273 kg A Base Length 47 3 1201 4 mm B Base Ext Width Closed 26 4 670 6 mm C Base Int Width Opened 39 3 998 0 mm D Mast Height 51 3 1304 0 mm E Lifting Height Lowest 21 5 546 4 mm F Lifting Height High...

Page 10: ...ecure it in place by inserting and tightening the long hex head bolt and nut at the top slot hole on the side of the bracket as following Make sure the mast is inserted behind the metal plate that is...

Page 11: ...f the bracket to secure the mast Insert the black plastic cover to the nut after the bolt is tightened Step 4 Reinsert and tighten the carriage bolt to the front slot hole of the bracket and the mast...

Page 12: ...ned insert the plastic cap Step 7 Secure the lower end of the actuator to the bracket on the mast using a pin and retaining ring as follows It is critical to have the motor part of the actuator to fac...

Page 13: ...12 Step 8 Secure the upper end of the actuator to the bracket on the boom using a pin and retaining ring as follows Step 9 Secure the spreader bar to the boom using a pin and retaining ring as follows...

Page 14: ...Power Control Unit 4 3 2 1 5 M5 SCREWS M4 SCREWS M4 UNLESS OTHERWISE SPECIFIED PART NUMBER DATE DRAWN BY 2920 PACIFIC DRIVE NORCROSS GA 30071 9 27 2017 ALL DIMENSIONS IN MM 1 6 6 30 30 120 0 1 0 2 0 3...

Page 15: ...e one that serves the needs of the patient while providing the patient with optimal safety Never interfere with the lift unless instructed by the attendant Have a doctor nurse or medical attendant exp...

Page 16: ...mproperly Keep long charger cord out of walkway where it poses a tripping hazard Have the charger port on the controller facing away from the wall for easy disconnection When removing the battery need...

Page 17: ...signs below The DC Charger must be connected The emergency stop button must be released The battery will not be charged if the emergency button is pressed in LCD Display Panel Signs When the emergenc...

Page 18: ...17 LED Indicator Green In Use Blank Standby Lifting Lowering Operating Lift Using Hand Control Operating Lift Using LCD Display Panel...

Page 19: ...w the LCD Display Panel will show the sign on the left either when the emergency stop button is released or when a button on the LCD Display Panel is pressed Lift operation is deactivated Battery need...

Page 20: ...Replacement with Head Support Polyester with PU Coating M L XL Liko Guldmann Disposable Replacement Nonwoven Disposable M L XL Liko Guldmann Disposable Replacement with Head Support Nonwoven Disposabl...

Page 21: ...1 Hook up F Point 2 Hook up E Insert F through E 8 Strap Sling A B G H C D E F Point 1 Hook up A C Point 2 Hook up B D Point 3 Hook up E Point 4 Hook up F Point 5 Hook up H Point 6 Hook up G Insert H...

Page 22: ...he surface 11 Reverse the above procedures when returning the user patient to bed Transfer From Wheelchair to Bed 1 Help the user lean forward slightly then slide the sling down between the chair and...

Page 23: ...isual inspection prior to use for the additional points below V The periodic inspection interval and the visual inspection points are listed below Note Bestcare assumes that the assembly instructions...

Page 24: ...h use for contamination from previous use Use isopropyl alcohol for any disinfection purpose Cleaning of the lift Cleaning of the sling Solvents or strong liquids or abrasive cleaning products will da...

Page 25: ...he user The Emergency Lowering Device is located at the top of the actuator shaft It is intended for use if the actuator or electronics fail to operate while the patient is suspended in midair The dev...

Page 26: ...usage The actuator will either go up or down but not both Replace your hand control as it is at the end of its life cycle Your control box may be malfunctioning There is a grinding sound inside the ac...

Page 27: ...suance of a return authorization will also be refused as the authorization will have expired The final disposition of warranty claims will be subject to our inspection of the returned items Bestcare L...

Page 28: ...Bestcare LLC 2920 Pacific Drive Norcross GA 30071 Ver 2021 09 www bestcarellc com 2021 Bestcare LLC...

Reviews: