Step 6: Install the hydraulic pump/electric actuator, and secure the lower
and upper ends of the pump/actuator to the bracket on the mast and
boom mast using a pin and retaining ring as follows.
Warning:
When installing the upper end of the
PUMP
, make sure
pump is aligned to the hole on bracket that is
closer
to the mast
.
When installing the upper end of the
ACTUATOR
, make sure align to
the hole on bracket that is
further
to the mast
.
PL400H Hydraulic Pump Setup
PL400HE Electric Actuator Setup
UNLESS OTHERWISE SPECIFIED:
SHEET:
SCALE:
PART NUMBER:
DESCRIPTION:
DATE:
DRAWN BY:
MATERIAL:
FINISH:
2920 PACIFIC DRIVE NORCROSS, GA 30071
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BESTCARE LLC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BESTCARE LLC IS PROHIBITED.
9/8/2017
1 of 1
LOUIS CHOW
PIN
PL500E-Pin
1:1
ALL DIMENSIONS IN MM
1-6
6-30
30-120
120-400
0.1 0.2
0.3
0.5
Install the spreader bar to the bracket at the end of the boom, and