FOR DUAL BLOWER UNIT, MAKE SURE THE
IMPELLERS ARE CORRECTLY INSTALLED, THE
INSERT WILL NOT WORK
PROPERLY
IF
REVERSED.
Both impellers are different in the dual blower, one
rotates clockwise and the other counterclockwise.
Each wheel and motor have an arrow and a number
on them, you have to match them correctly (see
drawing beside).
- 11 -
Secure the blower by installing 2 more no. 8 x 3/8” screws for the P5 blower and 4 more no. 8 x 3/8” screws for P8 into the locations
shown in the pictures below (single blower or dual blower). Reinstall impeller(s) and cover.
HD0080
HD0081
Single blower (P5)
18. INSTALL THE BLOWER (INTERIOR BLOWER)
(CONT’D)
Install (4) no. 8 x 3/8” screws into the location as shown in the pictures below (single blower or dual blower). Do not tighten
screws down fully, leave a 1/8” gap. Hang blower unit onto blower plate (screws through the large part of the keyhole). Slide the
blower to its position (screws in the small part of the keyhole). Tighten the (4) screws.
HD0044
HD0045
Single blower (P5)
Dual blower (P8)
WARNING
Never plug the 2-prong blower cord to the 3-prong power supply cord.
!
Plug the power supply to the 3-prong male connector (
A
) and the blower unit into
the 2-prong female receptacle (
B
) inside the insert.
HE0022
A
B
Dual blower (P8)
2
1
HD002
3
FRONT
HD0023
1
2