Installation Instructions for IDH Max 1300 Mortise Locks
BEST ACCESS SYSTEMS
A Division of Stanley Security Solutions, Inc
14
Installing the lock
For example, to address an IDH Max Lock with address
number 5, the binary equivalent number would be
00101 – OFF OFF ON OFF ON. See table below.
(16)
(8)
(4)
(2)
(1)
Reader
address
Switch
5
Switch
4
Switch
3
Switch
2
Switch
1
0
All off
1
ON
2
ON
3
ON
ON
4
ON
5
ON
ON
6
ON
ON
7
ON
ON
ON
8
ON
9
ON
ON
10
ON
ON
11
ON
ON
ON
12
ON
ON
13
ON
ON
ON
14
ON
ON
ON
15
ON
ON
ON
ON
16
ON
17
ON
ON
18
ON
ON
19
ON
ON
ON
20
ON
ON
21
ON
ON
ON
22
ON
ON
ON
23
ON
ON
ON
ON
24
ON
ON
25
ON
ON
ON
26
ON
ON
ON
27
ON
ON
ON
ON
28
ON
ON
ON
29
ON
ON
ON
ON
30
ON
ON
ON
ON
31
ON
ON
ON
ON
ON
12
3
4
5
6
7
8
ON
Figure 14 DIP switches on the Control Electronics circuit
board set to reader address 5 and 38,400 bps
baud rate and not end of line.
Switches
1–5 are reader
addressing
switches
Switches
6–7 are baud rate switches
Switch 8 is the
end-of-line switch;
set it to
ON if the lock is the last one
in the daisy change
.