Operation Instructions:
For ADB0002 Unit:
1. Place one foot on the grate (FS-GRATE) and step down
with heel to activate the spray.
2. Repeat the process with your other foot.
For
ADB0002-MH
Unit:
1. Grip the handle (FS-HNDL) with both hands to establish 3
points of contact.
2. Place one foot on the grate (FS-GRATE) and step down
with heel to activate the spray.
3. Repeat the process with your other foot.
For ADB0002
-BS Unit:
1. Grip the handle (FS-HNDL-C) above the manual boot
scrubber with both hands to establish 3 points of contact.
2. Place one foot in the brushes and push foot back and
forth to remove debris. Repeat the process with your
other foot.
3. Move to the footwear sanitizer and grip the handle (FS-
HNDL) above with both hands to establish 3 points of
contact.
4. Place one foot on the grate (FS-GRATE) and step down
with heel to activate the spray.
5. Repeat the process with your other foot.
Maintenance and Cleaning Instructions:
Note: Before performing any maintenance or cleaning,
disconnect the unit from the compressed air supply. After
maintenance or cleaning is complete, reconnect compressed air,
verify suction line and fittings are secure, and re-prime the unit
according to the Priming Instructions on page 3.
For ADB0002,
ADB0002-MH
, and ADB0002
-BS Units:
• Empty and clean collection basin (SS2-H)
o Lift up on the front of the grate and rotate the top
half of the unit to release from the base. Slide top
half of unit from the bracket (FS-GUARD).
o Stand top half of unit on short end. Setting unit
down in other position may cause damage to nozzle
assembly.
o Grab handle on front of collection basin and tip
up to empty. Basin can be sprayed down using an
appropriate cleaner per your plant’s sanitation
procedures, then rinsed.
• Cleaning top half
o
IMPORTANT:
The regulator and pump must be
protected from excessive moisture, and covered
during foaming/spraying, or cleaned by hand.
Check with your plant’s sanitation or maintenance
department for recommended procedure before
attempting to clean.
o Once cleaned, slide top half of unit back into place
on collection basin.
• Verify that the nozzle assembly is free of any debris or
blockage, and clean if necessary.
• Inspect all tubing for leaks or excessive wear. Make sure
all hose clamps and push fittings are in good condition
and properly secured.
For USP20031
Unit Only:
• Empty debris collection tray (DBTR).
• Remove brushes (USP20032
and
USP20033) by lifting
them out from the brush bracket. Clean if necessary.
Troubleshooting Instructions:
If footwear sanitizing unit will not spray:
• Verify that the Alpet® D2 pail is not empty.
• Verify that the unit is connected to an appropriate
compressed air source. This unit requires 50-80 psi (3.4-
5.5 bar) with 1 CFM (28.3 l/min) to operate. To maximize
unit lifespan and performance, compressed air should be
clean and dry. Note: If your air source has a high moisture
content, you may wish to install a water separator (WS-
20CFM) before the unit.
• Re-prime the unit, according to the Priming Instructions
on page 3.
• Check the nozzles and make sure they are not clogged
or blocked by debris. The spray tips (FCN120) may be
removed and cleaned if necessary.
• Check the suction line and strainer for debris and clean as
needed.
If footwear sanitizing unit is leaking liquid onto the floor:
• Verify the collection basin (SS2-H) is not full or
overflowing. Empty if necessary.
• Check all tubing connections and verify that none are