Page 3 of 8
User Manual: HACCP SmartStep
™
Footwear Sanitizing System | English
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Best Sanitizers, Inc. I 888.225.3267 I www.bestsanitizers.com
Installation Instructions:
For ADB0002 Unit:
1. Position footwear sanitizing unit in desired location.
2. Place Alpet® D2 Surface Sanitizer pail in close proximity to
sanitizing unit. Suction hose length should not exceed 8
ft. (2.4 m). Remove white shipping cap from pail, replace
with red safety adapter cap (USP20028) and suction line
(see page 7 for diagram). The HACCP SmartStep’s suction
tube is now connected to the pail’s internal dip tube.
3. Connect an air line to the air fitting (AP25).
4. Prime the unit according to the Priming Instructions.
For
ADB0002-
MH Unit:
1. Position footwear sanitizing unit in desired location.
2. Attach handle to handle bracket with bolts on the ends
(B5161834). Secure with set screws (B5161858 and
LNSS516).
3. Mount handle assembly to floor or wall (hardware not
included).
4. Lift up on the front of the grate and rotate the top half
of the unit to release from the base. Slide top half of unit
from the bracket (FS-GUARD).
5. Hook the plate (FS-FMP) on the underside of the collection
basin to the bracket at the base of the mounting handle.
6. Place Alpet® D2 Surface Sanitizer pail in close proximity to
sanitizing unit. Suction hose length should not exceed 8
ft. (2.4 m). Remove white shipping cap from pail, replace
with red safety adapter cap (USP20028) and suction line
to pail.
7. Connect an air line to the air fitting (AP25). Prime the unit
according to the Priming Instructions.
For ADB0002
-
BS Unit:
1. Position footwear sanitizing unit in desired location.
2. Attach handle to boot scrubber base with bolts on the
ends (B5161812). Secure with set screws (B5161834 and
LNSS516).
3. Slide debris tray (DBTR) under boot scrubber, lift up and
hook tray into slots on the front of the boot scrubber
frame to secure.
4. Connect debris shield (DBSH) by sliding hooks into the
slots on the back of the boot scrubber frame. Note:
Brushes (USP20032 and USP20033) must be removed
before installing/uninstalling debris shield.
5. Confirm that boot scrubber is in desired location and
mount to floor (hardware not included).
6. Position mounting bracket (FS-BPL) for footwear sanitizer
next to the boot scrubber and secure to the floor
(hardware not included).
7. Hook the plate (FS-FMP) on the underside of the collection
basin to the bracket at the base of the mounting handle.
8. Place Alpet® D2 Surface Sanitizer pail in close proximity to
sanitizing unit. Suction hose length should not exceed 8
ft. (2.4 m). Remove white shipping cap from pail, replace
with red safety adapter cap (USP20028) and suction line.
9. Connect an air line to the air fitting (AP25).
10. Prime the unit according to the Priming Instructions.
For USP20031 Unit:
1. Position boot scrubber unit in desired location.
2. Attach handle to boot scrubber base with bolts on the
ends (B5161812). Secure with set screws (B5161834 and
LNSS516).
3. Slide debris tray (DBTR) under boot scrubber, lift up and
hook tray into slots on the front of the boot scrubber
frame to secure.
4. Connect debris shield (DBSH) by sliding hooks into the
slots on the back the boot scrubber frame. Note: Brushes
(USP20032 and USP20033) must be removed before
installing/uninstalling
debris shield.
5. Confirm that boot scrubber is in desired location and
mount to floor (hardware not included).
6. Position mounting bracket (FS-BPL) for footwear sanitizer
next to the boot scrubber and secure to the floor
(hardware not included).
7. Hook the plate (FS-FMP) on the underside of the collection
basin to the mounting bracket (FS-BPL).
Priming Instructions:
Note: This unit is for use with fully protective footwear only. Do not
activate the unit if a user’s foot is not positioned inside the spray
guard (SS2-SH).
1. Verify that the Alpet® D2 Surface Sanitizer pail is full. Check all
external tubing connections and verify that none are loose or
leaking.
2. Place foot on the grate (FS-GRATE) and step down with heel
10-15 times or until all air has been purged from the suction
line.
3. Check bottom of footwear for proper sanitizer application. The
entire sole should be covered with a consistent spray pattern.