- 4 -
OPERATION
Controls
The hood is operated using the (5) push buttons located
on the front edge of the
hood.
The
Light Off/On
switch turns the lights on to low intensity and turns them off.
The
Light Dimmer
switch alternates light intensity from low to high.
The
Blower Off/Speed
switch turns the blower off and changes blower speed to
four different speed settings: high, medium-high, medium-low and low speed.
Depress and hold the button for 2 seconds to turn the blower off.
The
Blower On/Speed
switch turns the blower on to four different speed settings:
Low, medium-low, medium-high and high speed.
The
LED Display
:
•
Indicates blower speed selection from 1 (lowspeed) to 4 (high speed).
•
Flashes the blower speed when the 10-minutes delay off has been
activated.
•
After 30 hours of operation, the center segment of the display blinks and
remains lit, indicating that filters need to be cleaned.
The
Time Delay
switch activates a delay off feature. When pushed, the blower
will continue to operate at the current speed setting for 10-minutes before
automatically turning itself off.
The
Filter Alarm Reset
switch is used to reset the 30-hour filter timer. After filters
are cleaned or replaced, press this switch once to reset the filter clean alarm.
HEAT SENTRY™
Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a
device that will turn on or speed up the blower if it senses excessive heat above
the cooking surface.
1) If blower is OFF - it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting - it turns blower up to HIGH speed.
When the temperature level drops to normal, the blower will return to its original
setting.
WARNING
The HEAT SENTRY thermostat can start the blower even if the hood is turned
OFF. When this occurs, it is impossible to turn the blower OFF with its switch.
If you must stop the blower, do it from the main electrical panel.
Light Off/On
Light Dimmer
Blower Off/Speed
Blower On/Speed
LED Display
Time Delay/
Filter Alarm Reset