Besantek CABLE TRACER BST-CT103 Instruction Manual Download Page 4

-2-

when you turn on the unit.

The red LED flashes every 4 seconds as a visual  

indicator and reminder.

This is the mode of " Filter off ".

 

An instant press of the round "    " button to change  

 into the mode of " Filter on ".

The green LED flashes every 4 seconds as a visual  

indicator and reminder.

This is the mode of " Filter on " which can avoid the 

AC power line interference of 50Hz/60Hz.

 

The " Filter on " mode and the " Filter off " mode can  

 be  exchanged by an instant press.

 

The volume control can be adjusted to suit the  

environment. The volume can be increased

to overcome noise or decreased to reduce 

interference.

 

Touch the tip of the filter probe to the insulation of 

each suspect conductor.

 

Reception of tone will be loudest on the subject

wire. The brighter the LED, the stronger of tone signal 

detected.

 

Press the round "    " button for more than 3 seconds

to turn off the filter probe.

You can hear a long beep when you turn off the unit.

The filter probe also has the auto-off function 

(5 minutes).

C. Special Application

 

Plug in the phone jack activates the filter probe 

automatically without a long press of the round 

"    " button. It is equipped for connecting a lineman’s 

operation.

Summary of Contents for CABLE TRACER BST-CT103

Page 1: ...CABLE TRACER Filter Probe Tone Generator INSTRUCTION MANUAL BST CT103 ...

Page 2: ...INDEX PAGE 1 INTRODUCTION 1 2 FILTER PROBE 1 3 3 TONE GENERATOR 3 6 4 SPECIFICATION 7 8 5 MAINTENANCE 8 ...

Page 3: ...peration modes Filter on Filter off The auto off function 5 minutes prevents battery consumption Power supply is available in any 9V battery with a life of approximately 50 hours A phone jack is designed for headset or handset Flashlight function B Instructions Connecting the tone generator In terminated working cables Connect one test lead to a terminated wire and the other test lead to earth or ...

Page 4: ...be adjusted to suit the environment The volume can be increased to overcome noise or decreased to reduce interference Touch the tip of the filter probe to the insulation of each suspect conductor Reception of tone will be loudest on the subject wire The brighter the LED the stronger of tone signal detected Press the round button for more than 3 seconds to turn off the filter probe You can hear a l...

Page 5: ...odes of operation and two bi colored LEDs display line polarity for Lines 1 and 2 Figure 2 The tone and continuity cont test functions are only applied to Line 1 using the modular plug A tone selector switch located inside the test set is provided for choosing either a fast dual alternating tone or a slow dual alternating tone CAUTION DO NOT CONNECT TO AN ACTIVE AC CIRCUIT EXCEEDING 24V IN THIS MO...

Page 6: ...RITY TEST IDENTIFYING TIP RING SWITCH TO OFF a Connect the RED test lead to the side of one line and the BLACK lead to the side of another line b The LED will glow GREEN when you connect the RED test lead to the RING SIDE of the line c The LED will glow RED when you connect the RED test lead to the TIP SIDE of the line IDENTIFYING LINE CONDITION SWITCH TO OFF a Connect the RED test lead to the RIN...

Page 7: ...to the subject pair d If you switch the test set to CONT it will terminate the call on the subject line SENDING TONE SWITCH TO TONE CAUTION DO NOT CONNECT TO ANY ACTIVE AC CIRCUIT EXCEEDING 24V IN THIS MODE a Connect the test leads to the pair or attach one lead to ground and one lead to either side of the line See figure 1 b A fast dual alternating tone or a slow dual alternating tone can be sele...

Page 8: ... IN THIS MODE a Connect the test leads to the subject pair b Use a handset at the remote end and touch the wire end s with the clip lead s c Reception of tone is an indication of continuity MODULAR TESTING All above tests are available through the modular plug for line 1 only red and green wires COAX TESTING a To test unterminated coax connect red to outer shield and black to center conductor or r...

Page 9: ...ed Power source 9V battery 1 Dimensions 250 L 39 W 38 D mm Weight battery included Approx 180g Tone Generator Wave form Square Wave Frequency 1kHz 15 Over voltage protection 80V DC Alternating tone Fast and Slow Connection RJ11 connector alligator clip x 2 RJ45 connector Power source 9V battery 1 Dimensions 86 L 63 W 26 D mm Weight battery included Approx 130g ...

Page 10: ...h and mild detergent do not use abrasives or solvents B Battery Replacement The filter probe is maintenance free except for battery replacement Remove the screw from the battery compartment replace the 9V battery and reassemble Separate the case of the tone generator install a fresh 9V battery and reassemble DO NOT OVER TIGHTEN C Warranty limited solely to repair or replacement no warranty of merc...

Reviews: