-9-
In the presence of Phase (U>100V), the
“ ” symbol glows. In certain cases,
the “ ” symbol may light up in the
presence of static charges.
● CONTINUITY TEST
Performing a continuity test:
Connect the test leads to the component
or circuit under test.
The LCD will display the resistance value
under 2000Ω and display “O.L.” when it is
over 2000Ω.
buzzer sounds<200Ω.
● DIODE TEST
The red (L2+) test probe Connects to the
anode of diode and the black (L1) probe
connects to the cathode of diode, then
the LCD will display the voltage of diode.
The red probe and black probe exchange
to connect the diode, the the “O.L” diode
voltage will be displayed on the LCD.