(b) Measuring procedure:
1. C onnect specimen by test cable.
2. Switch @ the function rotary switch to turn on power
and select test voltage from 500V, 1 kV, 2.5kV or 5kV,
respectively.
3. Be sure that the cable connecting the specimen, if there
is a exterior voltage (above AC30V or DC30V) exerted,
beeper activates in response; and LCD displays
the warning picture as shown in the AC/DC voltage
measurement function:
2016-08-16 10:10
ACI..J 110U
60HZ
Now, test cannot be performed. To go on the test it
should remove the exterior voltage.
4. Then, press ®) TEST/ STOP button to test.
(1) Rotate another angle to lock®) TEST/ STOP button
for testing continuously.
(2) While test is running, beeper activates to remind
operator that test is underway.
(3) After the set test time is due (see Function 2: the
test time setting), test stops and system will
automatically lock down the test value.
(4) To read the test value on the LCD display
-8-