7
BEFORE
INSTALLATION
This
appliance
shall
only
be
installed
by
an
authorized
professional.
This
appliance
shall
be
installed
in
accordance
with
the
manufacturer’s
installation
instructions.
This
appliance
must
be
installed
in
accordance
with
the
norms
&
standards
of
the
country
where
it
will
be
installed.
The
installation
of
this
appliance
must
conform
to
local
codes
and
ordinances.
In
the
absence
of
local
codes,
Installations
must
conforms
to
American
National
Standards,
National
Fuel
Gas
Code
ANSI
Z223.1
–
latest
edition**
or
B149.1.
The
appliance,
when
installed,
must
be
electrically
grounded
in
accordance
with
local
codes
or,
in
the
absence
of
local
codes,
with
the
National
Electrical
Code,
ANSI/NFPA
70.
If
local
codes
permit,
a
flexible
metal
appliance
connection
with
the
new
AGA
or
CGA
certified
design,
max.
5
feet
(1,5
m)
long,
½”
I.D.
is
recommended
for
connecting
this
appliance
to
the
gas
supply
line.
Do
not
bend
or
damage
the
flexible
connector
when
moving
the
appliance.
This
appliance
must
be
used
with
the
pressure
regulator
provided.
The
regulator
shall
be
properly
installed
in
order
to
be
accessible
when
the
appliance
is
installed
in
its
final
location.
The
pressure
regulator
must
be
set
for
the
type
of
gas
to
be
used.
The
pressure
regulator
has
½”
female
pipe
thread.
The
appropriate
fitting
must
be
determined
based
on
the
size
of
your
gas
supply
line,
the
flexible
metal
connector
and
the
shutoff
valve.
The
appliance
must
be
isolated
from
the
gas
supply
piping
system
by
closing
its
individual
manual
shutoff
valve
during
any
pressure
testing
of
the
gas
supply
piping
system
at
test
pressures
equal
to
or
less
than
½
psi
(3.5
kPa).
All
opening
and
holes
in
the
wall
and
floor,
back
and
under
the
appliance
shall
be
sealed
before
installation
of
the
appliance.
A
manual
valve
shall
be
installed
in
an
accessible
location
in
the
gas
line
external
to
the
appliance
for
the
purpose
of
turning
on
or
shutting
off
gas
to
the
appliance
WARNING!
Do
not
use
aerosol
sprays
in
the
vicinity
of
this
appliance
while
it
is
in
operation
ROOM
VENTILATION:
An
exhaust
fan
may
be
used
with
the
appliance;
in
each
case
it
shall
be
installed
in
conformity
with
the
appropriate
national
and
local
standards.
Exhaust
hood
operation
may
affect
other
vented
appliances;
in
each
case
it
shall
be
installed
in
conformity
with
the
appropriate
national
and
local
standards.
TYPE
OF
GAS
This
appliance
is
shipped
from
the
factory
for
use
with
natural
gas.
For
use
with
propane
lp
gas
please
follow
the
conversion
procedure
described
on
pg.
17.
A
step
by
step
conversion
procedure
is
also
included
with
each
set
of
lp
gas
nozzles.
GAS
PRESSURE
The
maximum
inlet
gas
supply
pressure
incoming
to
the
gas
appliance
pressure
regulator
is
20’’
water
column
(5
kPa)
.
The
minimum
gas
supply
pressure
for
checking
the
regulator
setting
shall
be
at
least
1“
w.c.
(249
Pa)
above
the
inlet
specified
manifold
pressure
to
the
appliance
(this
operating
pressure
is
11”
w.c.
(2.75
kPa)
for
LP
Gas
and
4”
w.c.
(1.00
kPa)
for
Natural
Gas.