READ AND SAVE THESE  INSTRUCTIONS  BEFORE  YOU  START  

INSTALLING  THIS  RANGEHOOD

WARNING: - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:  

a) Never leave surface units unattended at high settings. Boilovers cause smoking and 

greasy spillovers that may ignite.  Heat oils slowly on low or medium setting.  

b) Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepes 

Suzette, Cherries Jubilee, Peppercorn Beef Flambé).  

c) Clean ventilating fans frequently.  Grease should not be allowed to accumulate on fan 

or filter.  

d) Use proper pan size.  Always use cookware appropriate for the size of the surface element.

WARNING: - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A 

RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:  

a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner.  

BE CAREFUL TO PREVENT BURNS.  If the flames do not go out immediately EVACUATE 

AND CALL THE FIRE DEPARTMENT.  

b) NEVER PICK UP A FLAMING PAN - You may be burned.  

c) DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will 

result.

d) Use an extinguisher ONLY if: 

    1.  You know you have a Class ABC extinguisher, and you already know how  to operate it.  

    2.  The fire is small and contained in the area where it started.  

    3.  The fire department is being called.  

    4.  You can fight the fire with your back to an exit.

* Based on "Kitchen Firesafety Tips" published by NFPA

WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, do not use this 

fan with any solid-state speed control device.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO 

PERSONS, OBSERVE THE FOLLOWING:  

1.  Use this unit only in the manner intended by the manufacturer. If you have any 

questions, contact the manufacturer.

2.  Before servicing or cleaning unit, switch power off at service panel and lock the 

service disconnecting means to prevent power from being switched on acciden-

tally. When the service disconnecting means cannot be locked, securely fasten a 

prominent warning device, such as a tag, to the service panel.

CAUTION: For General Ventilating Use Only.  Do Not Use To Exhaust Hazardous  or  

Explosive Materials and Vapors.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO 

PERSONS, OBSERVE THE FOLLOWING: 
1. 

Installation Work And Electrical Wiring Must Be Done By Qualified Person(s) In Accor

-

dance With All Applicable Codes And Standards, Including Fire-Rated Construction.  

2. 

Sufficient air is needed for proper combustion and exhausting of gases through 

the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the 

heating equipment manufacturer's guideline and safety standards such as those 

published by the National Fire Protection Association (NFPA), and the American 

Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and 

the local code authorities.

3.  When cutting or drilling into wall or ceiling, do not damage electrical wiring and 

other hidden utilities.

4.  Ducted fans must always be vented to the outdoors.

Summary of Contents for KTV30XV

Page 1: ...KTV30XV Installation Instructions Use and Care Information Instructions d installation Utilisez et d entretien...

Page 2: ...RNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK do not use this fan with any solid state speed control device WARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS OBSERVE THE FO...

Page 3: ...MENTS Determine which venting method is best for your application Ductwork can extend either through the wall or the roof The length of the ductwork and the number of elbows should be kept to a minimu...

Page 4: ...ollow electrical requirements may result in a fire WARNING State of California Proposition 65 Warning US only WARNING This product contains chemicals known to the State of California to cause cancer a...

Page 5: ...or maximum effectiveness Also consult the cooktop manufacturer s recommendation NOTE If direct rear venting use the side dimensional diagram below on the right For top venting comes standard in this p...

Page 6: ...6 30 RANGEHOOD REAR INFORMATION Palazzi Walter 15 Nov 2019 Released...

Page 7: ...1 and 2 show vertical and horizontal installations for this unit FIGURE 3 shows recirculating installation The KTV30XV requires 6 round ductwork To ensure that the blower performs to its highest poss...

Page 8: ...24 of straight duct between elbows if more than one is used Do not install two elbows together If you must elbow right away do it as far away from the hood s exhaust opening as possible RECIRCULATING...

Page 9: ...top setting to the bottom setting by removing the four phillips screws 5 Tighten the rangehood to the cabinet by rotating the screws with a phillips screw driver 6 A grey vinyl strip FIGURE 7 is incl...

Page 10: ...g plug The plug must be plugged into an outlet that is properly installed and grounded WARNING Improper grounding can result in a risk of electric shock Consult a qualified electrician if the groundin...

Page 11: ...on the blower and light will automatically operate when the visor is opened and shut off when the visor is closed For Best Results Starttherangehoodseveralminutesbeforecookingtodevelop FIGURE 10 ont...

Page 12: ...or more frequently with heavy usage Open the visor by pulling it RemovetheFilter pushingittowardsthebackof the unit and at the same time pulling downward RemovethesaturatedActivatedCharcoalFilters as...

Page 13: ......

Page 14: ......

Reviews: